We've been using WiX for a while now, and despite the usual gripes about ease of use, it's going reasonably well. What I'm looking for is useful advice regarding:

  • Setting up a WiX project (layout, references, file patterns)
  • Integrating WiX into solutions, and build/release processes
  • Configuring installers for new installations and upgrades
  • Any good WiX hacks you'd like to share
6
  • have a look at gui4wix.codeplex.com
    – TarunG
    Jul 12, 2011 at 6:58
  • 10
    Closed as not constructive? I've learnt heaps from asking this question! A little consistency from StackOverflow would also be nice...e.g. stackoverflow.com/questions/550632/…
    – si618
    Feb 22, 2012 at 5:12
  • 15
    It got '203' Ups, that's enough for it to prove its usefulness .
    – TarunG
    Feb 23, 2012 at 1:47
  • SO questions must have a definitive, correct answer; open-ended questions make the questions people ask about actual problems drop off the front page. faq @Si.: That policy has always been there AFAIK, but it's better enforced now; that question is almost three years old.
    – Jim Dagg
    Jun 22, 2012 at 19:03
  • Fair enough Jim, it is an open-ended question, and I guess it's up to SO community to decide, but I have to say that closing it as not constructive seems odd, given that I and by the looks of it, many other people have found this question useful (e.g. goo.gl/Zqp2X), and that it fits very well with the practical, answerable questions based on actual problems that you face part of the FAQ.
    – si618
    Aug 13, 2012 at 4:43

31 Answers 31

157
votes
  1. Keep variables in a separate wxi include file. Enables re-use, variables are faster to find and (if needed) allows for easier manipulation by an external tool.

  2. Define Platform variables for x86 and x64 builds

    <!-- Product name as you want it to appear in Add/Remove Programs-->
    <?if $(var.Platform) = x64 ?>
      <?define ProductName = "Product Name (64 bit)" ?>
      <?define Win64 = "yes" ?>
      <?define PlatformProgramFilesFolder = "ProgramFiles64Folder" ?>
    <?else ?>
      <?define ProductName = "Product Name" ?>
      <?define Win64 = "no" ?>
      <?define PlatformProgramFilesFolder = "ProgramFilesFolder" ?>
    <?endif ?>
    
  3. Store the installation location in the registry, enabling upgrades to find the correct location. For example, if a user sets custom install directory.

     <Property Id="INSTALLLOCATION">
        <RegistrySearch Id="RegistrySearch" Type="raw" Root="HKLM" Win64="$(var.Win64)"
                  Key="Software\Company\Product" Name="InstallLocation" />
     </Property>
    

    Note: WiX guru Rob Mensching has posted an excellent blog entry which goes into more detail and fixes an edge case when properties are set from the command line.

    Examples using 1. 2. and 3.

    <?include $(sys.CURRENTDIR)\Config.wxi?>
    <Product ... >
      <Package InstallerVersion="200" InstallPrivileges="elevated"
               InstallScope="perMachine" Platform="$(var.Platform)"
               Compressed="yes" Description="$(var.ProductName)" />
    

    and

    <Directory Id="TARGETDIR" Name="SourceDir">
      <Directory Id="$(var.PlatformProgramFilesFolder)">
        <Directory Id="INSTALLLOCATION" Name="$(var.InstallName)">
    
  4. The simplest approach is always do major upgrades, since it allows both new installs and upgrades in the single MSI. UpgradeCode is fixed to a unique Guid and will never change, unless we don't want to upgrade existing product.

    Note: In WiX 3.5 there is a new MajorUpgrade element which makes life even easier!

  5. Creating an icon in Add/Remove Programs

    <Icon Id="Company.ico" SourceFile="..\Tools\Company\Images\Company.ico" />
    <Property Id="ARPPRODUCTICON" Value="Company.ico" />
    <Property Id="ARPHELPLINK" Value="http://www.example.com/" />
    
  6. On release builds we version our installers, copying the msi file to a deployment directory. An example of this using a wixproj target called from AfterBuild target:

    <Target Name="CopyToDeploy" Condition="'$(Configuration)' == 'Release'">
      <!-- Note we append AssemblyFileVersion, changing MSI file name only works with Major Upgrades -->
      <Copy SourceFiles="$(OutputPath)$(OutputName).msi" 
            DestinationFiles="..\Deploy\Setup\$(OutputName) $(AssemblyFileVersion)_$(Platform).msi" />
    </Target>
    
  7. Use heat to harvest files with wildcard (*) Guid. Useful if you want to reuse WXS files across multiple projects (see my answer on multiple versions of the same product). For example, this batch file automatically harvests RoboHelp output.

    @echo off  
    robocopy ..\WebHelp "%TEMP%\WebHelpTemp\WebHelp" /E /NP /PURGE /XD .svn  
    "%WIX%bin\heat" dir "%TEMP%\WebHelp" -nologo -sfrag -suid -ag -srd -dir WebHelp -out WebHelp.wxs -cg WebHelpComponent -dr INSTALLLOCATION -var var.WebDeploySourceDir 
    

    There's a bit going on, robocopy is stripping out Subversion working copy metadata before harvesting; the -dr root directory reference is set to our installation location rather than default TARGETDIR; -var is used to create a variable to specify the source directory (web deployment output).

  8. Easy way to include the product version in the welcome dialog title by using Strings.wxl for localization. (Credit: saschabeaumont. Added as this great tip is hidden in a comment)

    <WixLocalization Culture="en-US" xmlns="http://schemas.microsoft.com/wix/2006/localization">
        <String Id="WelcomeDlgTitle">{\WixUI_Font_Bigger}Welcome to the [ProductName] [ProductVersion] Setup Wizard</String>
    </WixLocalization>
    
  9. Save yourself some pain and follow Wim Coehen's advice of one component per file. This also allows you to leave out (or wild-card *) the component GUID.

  10. Rob Mensching has a neat way to quickly track down problems in MSI log files by searching for value 3. Note the comments regarding internationalization.

  11. When adding conditional features, it's more intuitive to set the default feature level to 0 (disabled) and then set the condition level to your desired value. If you set the default feature level >= 1, the condition level has to be 0 to disable it, meaning the condition logic has to be the opposite to what you'd expect, which can be confusing :)

    <Feature Id="NewInstallFeature" Level="0" Description="New installation feature" Absent="allow">
      <Condition Level="1">NOT UPGRADEFOUND</Condition>
    </Feature>
    <Feature Id="UpgradeFeature" Level="0" Description="Upgrade feature" Absent="allow">
      <Condition Level="1">UPGRADEFOUND</Condition>
    </Feature>
    
4
  • About adding the icon in the Add/Remove Programs, it EXACTLY what I was looking for. Where do you stick those three lines? +1 for sheer awesomeness.
    – Everett
    Apr 2, 2009 at 14:34
  • I tend to place them just after (and obviously below) the <Package> element. Have a look at the schema for validity wix.sourceforge.net/manual-wix3/schema_index.htm
    – si618
    Apr 2, 2009 at 14:57
  • +1, wish I could do +100, this is the single most useful bit of Wix information I have stumbled upon.
    – Tim Long
    Jul 19, 2011 at 23:32
  • Thanks Tim! Rob Mensching, Bob Arson, Wim Coehen and others deserve the kudos for sharing their knowledge.
    – si618
    Jul 20, 2011 at 1:51
38
votes

Checking if IIS is installed:

<Property Id="IIS_MAJOR_VERSION">
    <RegistrySearch Id="CheckIISVersion" Root="HKLM" Key="SOFTWARE\Microsoft\InetStp" Name="MajorVersion" Type="raw" />
</Property>

<Condition Message="IIS must be installed">
    Installed OR IIS_MAJOR_VERSION
</Condition>

Checking if IIS 6 Metabase Compatibility is installed on Vista+:

<Property Id="IIS_METABASE_COMPAT">
    <RegistrySearch Id="CheckIISMetabase" Root="HKLM" Key="SOFTWARE\Microsoft\InetStp\Components" Name="ADSICompatibility" Type="raw" />
</Property>

<Condition Message="IIS 6 Metabase Compatibility feature must be installed">
    Installed OR ((VersionNT &lt; 600) OR IIS_METABASE_COMPAT)
</Condition>
0
34
votes

Keep all IDs in separate namespaces

  • Features begin with F. Examples: F.Documentation, F.Binaries, F.SampleCode.
  • Components begin with C. Ex: C.ChmFile, C.ReleaseNotes, C.LicenseFile, C.IniFile, C.Registry
  • CustomActions are CA. Ex: CA.LaunchHelp, CA.UpdateReadyDlg, CA.SetPropertyX
  • Files are Fi.
  • Directories are Di.
  • and so on.

I find this helps immensely in keeping track of all the various id's in all the various categories.

1
  • I don't use namespaces but I append the IDs; for example: ExamplesFeature, ChmFileComponent. I guess I love typing ;-)
    – dvdvorle
    May 9, 2012 at 9:48
25
votes

Fantastic question. I'd love to see some best practices shown.

I've got a lot of files that I distribute, so I've set up my project into several wxs source files.

I have a top level source file which I call Product.wxs which basically contains the structure for the installation, but not the actual components. This file has several sections:

<Product ...>
  <Package ...>
    <Media>... 
   <Condition>s ...
   <Upgrade ..>
   <Directory> 
        ...
   </Directory>
   <Feature>
      <ComponentGroupRef ... > A bunch of these that
   </Feature>
   <UI ...>
   <Property...>
   <Custom Actions...>
   <Install Sequences....
  </Package>
</Product>

The rest of the .wix files are composed of Fragments that contain ComponentGroups which are referenced in the Feature tag in the Product.wxs. My project contains a nice logical grouping of the files that I distribute

<Fragment>
   <ComponentGroup>
     <ComponentRef>
     ....
    </ComponentGroup>
    <DirectoryRef>
      <Component... for each file
      .... 
    </DirectoryRef>
</Fragment>

This isn't perfect, my OO spider sense tingles a bit because the fragments have to reference names in the Product.wxs file (e.g. the DirectoryRef) but I find it easier to maintain that a single large source file.

I'd love to hear comments on this, or if anyone has any good tips too!

3
  • Our setup is also very similar to this approach. It's good because we can use our equivalent of Products.wxs as our base setup for a variety of products.
    – si618
    Feb 8, 2009 at 3:23
  • @Peter Tate: your spider sense is correct. See my answer about directory aliasing.
    – Wim Coenen
    Feb 26, 2009 at 20:01
  • I take the same approach: Product.wxs with layout is static, and a build task (heat.exe) generates my Content.wxs file
    – timvw
    Jun 12, 2010 at 19:02
20
votes

Add a checkbox to the exit dialog to launch the app, or the helpfile.

...

<!-- CA to launch the exe after install -->
<CustomAction Id          ="CA.StartAppOnExit"
              FileKey     ="YourAppExeId"
              ExeCommand  =""
              Execute     ="immediate"
              Impersonate ="yes"
              Return      ="asyncNoWait" />

<!-- CA to launch the help file -->
<CustomAction Id         ="CA.LaunchHelp"
              Directory  ="INSTALLDIR"
              ExeCommand ='[WindowsFolder]hh.exe IirfGuide.chm'
              Execute    ="immediate"
              Return     ="asyncNoWait" />

<Property Id="WIXUI_EXITDIALOGOPTIONALCHECKBOXTEXT"
          Value="Launch MyApp when setup exits." />

<UI>
  <Publish Dialog  ="ExitDialog"
           Control ="Finish"
           Order   ="1"
           Event   ="DoAction"
           Value   ="CA.StartAppOnExit">WIXUI_EXITDIALOGOPTIONALCHECKBOXTEXT</Publish>
</UI>

If you do it this way, the "standard" appearance isn't quite right. The checkbox is always a gray background, while the dialog is white:

alt text http://www.dizzymonkeydesign.com/blog/misc/adding-and-customizing-dlgs-in-wix-3/images/exit_dlg_1.gif

One way around this is to specify your own custom ExitDialog, with a differently-located checkbox. This works, but seems like a lot of work just to change the color of one control. Another way to solve the same thing is to post-process the generated MSI to change the X,Y fields in the Control table for that particular CheckBox control. The javascript code looks like this:

var msiOpenDatabaseModeTransact = 1;
var filespec = WScript.Arguments(0);
var installer = new ActiveXObject("WindowsInstaller.Installer");
var database = installer.OpenDatabase(filespec, msiOpenDatabaseModeTransact);
var sql = "UPDATE `Control` SET `Control`.`Height` = '18', `Control`.`Width` = '170'," +
          " `Control`.`Y`='243', `Control`.`X`='10' " +
          "WHERE `Control`.`Dialog_`='ExitDialog' AND " + 
          "  `Control`.`Control`='OptionalCheckBox'";
var view = database.OpenView(sql);
view.Execute();
view.Close();
database.Commit();

Running this code as a command-line script (using cscript.exe) after the MSI is generated (from light.exe) will produce an ExitDialog that looks more professional:

alt text http://www.dizzymonkeydesign.com/blog/misc/adding-and-customizing-dlgs-in-wix-3/images/exit_dlg_2.gif

7
  • Ha! Not my blog. I read it too. And I have a link to the blog entry in the text above. But they did it differently than I did. I like my way better.!!
    – Cheeso
    Nov 26, 2009 at 4:34
  • 1
    Thanks for the js, very helpful! One thing that I had to change in the wxs is replace WIXUI_EXITDIALOGOPTIONALCHECKBOX with WIXUI_EXITDIALOGOPTIONALCHECKBOX = 1 and NOT Installed inside <Publish> Jul 10, 2010 at 8:36
  • Is there a way to make the check box checked by default?
    – Alek Davis
    Sep 24, 2010 at 23:56
  • To check the box by default, I used this: <Property Id="WIXUI_EXITDIALOGOPTIONALCHECKBOX" Value="1"/>
    – Alek Davis
    Sep 30, 2010 at 16:37
  • Seems like a nifty solution, but just how do I use it? Is there some way to put the js inside the <AfterBuild> element in my wixproj? Or since you refer to running it from the command line, is it better as a post-build event, in which case, what's a good js command-line interpreter for Windows?
    – vanmelle
    Oct 5, 2010 at 0:40
18
votes

Creating Live, Test, Training, ... versions using the same source files.

In a nutshell: Create unique UpgradeCode for each installer and automagically define the first character of each Guid for each installer, leaving the remaining 31 unique.

Prerequisites

Assumptions

  • WiX variables are used to define UpgradeCode, ProductName, InstallName.
  • You already have a working installer. I wouldn't attempt this until you do.
  • All your Components are kept in one file (Components.wxs). This process will work if you have multiple files, there will just be more work to do.

Directory Structure

  • Setup.Library
    • All wxs files (Components, Features, UI Dialogs, ...)
    • Common.Config.wxi (ProductCode="*", ProductVersion, PlatformProgramFilesFolder, ...)
  • Setup.Live (wixproj)
    • Link all Setup.Library files using "Add Existing File" -> "Add As Link" (the little down arrow button right next to the Add button in Visual Studio)
    • Config.wxi (has unique UpgradeCode, ProductName, InstallName, ...)
  • Setup.Test, ...
    • as per live but Config.wxi is configured for Test environment.

Process

  • Create Setup.Library directory and move all your wxs and wxi files (except Config.wxi) from existing project.
  • Create Setup.Live, Setup.Test, etc as per normal wixproj.
  • Add BeforeBuild target in wixproj in Setup.Live, etc to perform MSBuild Community Task FileUpdate to modify Guids (I used A for Live, B for Test and C for training)
  • Add AfterBuild target to revert Components.wxs Guids back to 0.
  • Verify with Orca that each component in each MSI has the modified guid.
  • Verify that original guids are restored.
  • Verify that each MSI is installing (and upgrading) correct product and location.

Example Config.wxi

<?xml version="1.0" encoding="utf-8"?>
<Include>
<!-- Upgrade code should not change unless you want to install 
     a new product and have the old product remain installed, 
     that is, both products existing as separate instances. -->
<?define UpgradeCode = "YOUR-GUID-HERE" ?>

<!-- Platform specific variables -->
<?if $(var.Platform) = x64 ?>
  <!-- Product name as you want it to appear in Add/Remove Programs-->
  <?define ProductName = "Foo 64 Bit [Live]" ?>
<?else ?>
  <?define ProductName =  "Foo [Live]" ?>
<?endif ?>

<!-- Directory name used as default installation location -->
<?define InstallName = "Foo [Live]" ?>

<!-- Registry key name used to store installation location -->
<?define InstallNameKey = "FooLive" ?>

<?define VDirName = "FooLive" ?>
<?define AppPoolName = "FooLiveAppPool" ?>
<?define DbName = "BlahBlahLive" ?>
</Include>

Example Config.Common.wxi

<?xml version="1.0" encoding="utf-8"?>
<Include>
<!-- Auto-generate ProductCode for each build, release and upgrade -->
<?define ProductCode = "*" ?>

<!-- Note that 4th version (Revision) is ignored by Windows Installer -->
<?define ProductVersion = "1.0.0.0" ?>

<!-- Minimum version supported if product already installed and this is an upgrade -->
<!-- Note that 4th version (Revision) is ignored by Windows Installer -->
<?define MinimumUpgradeVersion = "0.0.0.0" ?>

<!-- Platform specific variables -->
<?if $(var.Platform) = x64 ?>
   <?define Win64 = "yes" ?>
   <?define PlatformProgramFilesFolder = "ProgramFiles64Folder" ?>
<?else ?>
   <?define Win64 = "no" ?>
   <?define PlatformProgramFilesFolder = "ProgramFilesFolder" ?>
<?endif ?>

<?define ProductManufacturer = "Foo Technologies"?>

<!-- Decimal Language ID (LCID) for the Product. Used for localization. -->
<?define ProductLanguage = "1033" ?>

<?define WebSiteName = "DefaultWebSite" ?>
<?define WebSitePort = "80" ?>

<?define DbServer = "(local)" ?>
</Include>

Example Components.wxs

<?xml version="1.0" encoding="utf-8"?>
<Wix xmlns="http://schemas.microsoft.com/wix/2006/wi">
  <!-- The pre-processor variable which allows the magic to happen :) -->
  <?include $(sys.CURRENTDIR)\Config.wxi?>
  <?include ..\Setup.Library\Config.Common.wxi?>
  <Fragment Id="ComponentsFragment">
    <Directory Id="TARGETDIR" Name="SourceDir">
      <Directory Id="$(var.PlatformProgramFilesFolder)">
        <Directory Id="INSTALLLOCATION" Name="$(var.InstallName)">
          <Component Id="ProductComponent" Guid="0XXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX" KeyPath="yes">
          ...

Note: I would now suggest leaving the Guid attribute out of Component (equivalent of *), using one file per component and setting the file as the keypath. This removes the need for calling ModifyComponentsGuids and RevertComponentsGuids targets shown below. This might not be possible for all your components though.

Example Setup.Live.wixproj

<Import Project="$(MSBuildExtensionsPath)\MSBuildCommunityTasks\MSBuild.Community.Tasks.Targets" />
<Target Name="BeforeBuild">
  <CallTarget Targets="ModifyComponentsGuids" />
</Target>
<Target Name="AfterBuild">
  <CallTarget Targets="RevertComponentsGuids" />
</Target>
<!-- Modify the first character of every Guid to create unique value for Live, Test and Training builds -->
<Target Name="ModifyComponentsGuids">
  <FileUpdate Files="..\Setup.Library\Components.wxs" Regex="Guid=&quot;([a-f]|[A-F]|\d)" ReplacementText="Guid=&quot;A" />
</Target>
<!-- Revert the first character of every Guid back to initial value -->
<Target Name="RevertComponentsGuids">
  <FileUpdate Files="..\Setup.Library\Components.wxs" Regex="Guid=&quot;([a-f]|[A-F]|\d)" ReplacementText="Guid=&quot;0" />
</Target>

Final thoughts

  • This process should also work for creating different installers for different merge modules (Live, Test, ... as features) for the same installer. I went with different installers as it seemed a safer option, there is more risk that someone might upgrade Live instead of Training if they're on the same box and you just use features for the different merge modules.
  • If you use your MSI to perform upgrades as well as new installs i.e. the major upgrade only approach, and you save your installation location in the registry, remember to create a variable for the key name for each install.
  • We also create variables in each Config.wxi to enable unique virtual directory names, application pools, database names, et cetera for each installer.

UPDATE 1: Auto-generating component Guids removes the need for calling FileUpdate task if you create component with Guid="*" for each file, setting the file as the keypath.

UPDATE 2: One of the issues we've come up against is if you don't auto-generate your component Guid's and the build fails, then the temp files need to be manually deleted.

UPDATE 3: Found a way to remove reliance on svn:externals and temporary file creation. This makes the build process more resilient (and is best option if you can't wildcard your Guids) and less brittle if there is a build failure in light or candle.

UPDATE 4: Support for Multiple Instances using instance transforms is in WiX 3.0+, definitely also worth a look.

1
  • +1 for the MSBuild Community Tasks reference, love that package
    – BozoJoe
    Nov 12, 2010 at 18:21
17
votes

Using the Msi Diagnostic logging to get detailed failure Information

msiexec /i Package.msi /l*v c:\Package.log

Where

Package.msi
is the name of your package and
c:\Package.log
is where you want the output of the log

Msi Error Codes

Wix Intro Video
Oh and Random Wix intro video featuring "Mr. WiX" Rob Mensching is "conceptual big picture" helpful.

3
  • 2
    +1 It would be much better if we could enable logging from within Wix instead of the command line.
    – si618
    Jun 4, 2010 at 11:04
  • 3
    WiX does. Set the MsiLogging property. Only supported by Windows Installer 4.0+. Nov 22, 2010 at 14:07
  • Thank you much "Mr. Wix". Gotta check that out.
    – Terrance
    Nov 22, 2010 at 15:22
17
votes

Use Javascript CustomActions because they're soooo easy

People have said that Javascript is the wrong thing to use for MSI CustomActions. Reasons given: hard to debug, hard to make it reliable. I don't agree. It's not hard to debug, certainly no harder than C++. Its just different. I found writing CustomActions in Javascript to be super easy, much easier than using C++. Much faster. And just as reliable.

There's just one drawback: Javascript CustomActions can be extracted via Orca, whereas a C/C++ CA would require reverse-engineering. If you consider your installer magic to be protected intellectual property, you will want to avoid script.

If you use script, you just need to start with some structure. Here's some to get you started.


Javascript "boilerplate" code for CustomAction:

//
// CustomActions.js 
// 
// Template for WIX Custom Actions written in Javascript.
// 
// 
// Mon, 23 Nov 2009  10:54
// 
// ===================================================================


// http://msdn.microsoft.com/en-us/library/sfw6660x(VS.85).aspx
var Buttons = {
        OkOnly           : 0,
        OkCancel         : 1,
        AbortRetryIgnore : 2,
        YesNoCancel      : 3
};

var Icons = {
        Critical         : 16,
        Question         : 32,
        Exclamation      : 48,
        Information      : 64
};

var MsgKind = {
        Error            : 0x01000000,
        Warning          : 0x02000000,
        User             : 0x03000000,
        Log              : 0x04000000
};

// http://msdn.microsoft.com/en-us/library/aa371254(VS.85).aspx
var MsiActionStatus = {
        None             : 0,
        Ok               : 1, // success
        Cancel           : 2,
        Abort            : 3,
        Retry            : 4, // aka suspend?
        Ignore           : 5  // skip remaining actions; this is not an error.
};


function MyCustomActionInJavascript_CA() {
    try {
        LogMessage("Hello from MyCustomActionInJavascript");
        // ...do work here...
        LogMessage("Goodbye from MyCustomActionInJavascript");
    }
    catch (exc1) {
        Session.Property("CA_EXCEPTION") = exc1.message ;
        LogException(exc1);
        return MsiActionStatus.Abort;
    }
    return MsiActionStatus.Ok;
}

// Pop a message box.  also spool a message into the MSI log, if it is enabled. 
function LogException(exc) {
    var record = Session.Installer.CreateRecord(0);
    record.StringData(0) = "CustomAction: Exception: 0x" + decimalToHexString(exc.number) + " : " + exc.message;
    Session.Message(MsgKind.Error + Icons.Critical + Buttons.btnOkOnly, record);
}


// spool an informational message into the MSI log, if it is enabled. 
function LogMessage(msg) {
    var record = Session.Installer.CreateRecord(0);
    record.StringData(0) = "CustomAction:: " + msg;
    Session.Message(MsgKind.Log, record);
}


// http://msdn.microsoft.com/en-us/library/d5fk67ky(VS.85).aspx
var WindowStyle = {
    Hidden : 0,
    Minimized : 1,
    Maximized : 2
};

// http://msdn.microsoft.com/en-us/library/314cz14s(v=VS.85).aspx
var OpenMode = {
    ForReading : 1,
    ForWriting : 2,
    ForAppending : 8
};

// http://msdn.microsoft.com/en-us/library/a72y2t1c(v=VS.85).aspx
var SpecialFolders = {
    WindowsFolder : 0, 
    SystemFolder :  1, 
    TemporaryFolder : 2
};

// Run a command via cmd.exe from within the MSI
function RunCmd(command)
{
    var wshell = new ActiveXObject("WScript.Shell");
    var fso = new ActiveXObject("Scripting.FileSystemObject");
    var tmpdir = fso.GetSpecialFolder(SpecialFolders.TemporaryFolder);
    var tmpFileName = fso.BuildPath(tmpdir, fso.GetTempName());

    LogMessage("shell.Run("+command+")");

    // use cmd.exe to redirect the output
    var rc = wshell.Run("%comspec% /c " + command + "> " + tmpFileName, WindowStyle.Hidden, true);
    LogMessage("shell.Run rc = "  + rc);

    // here, optionally parse the output of the command 
    if (parseOutput) {
        var textStream = fso.OpenTextFile(tmpFileName, OpenMode.ForReading);
        while (!textStream.AtEndOfStream) {
            var oneLine = textStream.ReadLine();
            var line = ParseOneLine(oneLine);
                ...
        }
        textStream.Close();
    }

    if (deleteOutput) {
        fso.DeleteFile(tmpFileName);
    }

    return {
        rc : rc,
        outputfile : (deleteOutput) ? null : tmpFileName
    };
}

Then, register the custom action with something like this:

<Fragment>
  <Binary Id="IisScript_CA" SourceFile="CustomActions.js" />

  <CustomAction Id="CA.MyCustomAction"
              BinaryKey="IisScript_CA"
              JScriptCall="MyCustomActionInJavascript_CA"
              Execute="immediate"
              Return="check" />
</Fragmemt>

You can, of course, insert as many Javascript functions as you like, for multiple custom actions. One example: I used Javascript to do a WMI query on IIS, to get a list of existing websites, to which an ISAPI filter could be installed. This list was then used to populate a listbox shown later in the UI sequence. All very easy.

On IIS7, there is no WMI provider for IIS, so I used the shell.Run() approach to invoke appcmd.exe to perform the work. Easy.

Related question: About Javascript CustomActions

1
  • 2
    +1 I find the DTF approach to be easy to setup, but javascript could be useful too.
    – si618
    Nov 26, 2009 at 4:33
12
votes

Peter Tate has already shown how you can define reusable ComponentGroup definitions in separate wix fragments. Some additional tricks related to this:

Directory Aliasing

The component group fragments don't need to know about directories defined by the main product wxs. In your component group fragment you can talk about a folder like this:

<DirectoryRef Id="component1InstallFolder">
...
</DirectoryRef>

Then the main product can alias one of its directories (e.g. "productInstallFolder") like this:

<Directory Id="productInstallFolder" Name="ProductName">
   <!-- not subfolders (because no Name attribute) but aliases for parent! -->
   <Directory Id="component1InstallFolder"/> 
   <Directory Id="component2InstallFolder"/> 
</Directory>

Dependency Graph

ComponentGroup elements can contain ComponentGroupRef child elements. This is great if you have a big pool of reusable components with a complex dependency graph between them. You just set up a ComponentGroup in its own fragment for each component and declare the dependencies like this:

<ComponentGroup Id="B">
   <ComponentRef Id="_B" />
   <ComponentGroupRef Id="A">
</ComponentGroup>

If you now reference component group "B" in your setup because it is a direct dependency of your application, it will automatically pull in component group "A" even if the application author never realized that it was a dependency of "B". It "just works" as long as you don't have any circular dependencies.

Reusable wixlib

The above dependency graph idea works best if you compile the big-pool-o-reusable-components into a reusable wixlib with lit.exe. When creating an application setup, you can reference this wixlib much like a wixobj file. The candle.exe linker will automatically eliminate any fragments that are not "pulled in" by the main product wxs file(s).

12
votes

I'm surprised no one has mentioned using T4 to generate the WXS file during build. I learned about this by way of Henry Lee @ New Age Solutions.

Essentially, you create a custom MSBuild task to execute a T4 template, and that template outputs the WXS just before the Wix project is compiled. This allows you to (depending on how you implement it) automatically include all assemblies output from compiling another solution (meaning that you no longer have to edit the wxs ever time you add a new assembly).

5
  • 2
    +1 that's really nice, I'm not worried so much about assemblies, but our web projects can have problems with aspx pages and other artifacts (images, css) that are added to the project but not WiX.
    – si618
    Dec 14, 2009 at 23:13
  • 4
    For future visitors, Wix 3.5 has an utility heat.exe that does this harvesting automatically
    – Mrchief
    Aug 23, 2011 at 17:47
  • @Mrchief - I don't believe Heat picks up referenced assemblies that are copied local - this is apparently planned for 4.0 though. Reference: sourceforge.net/tracker/… Aug 29, 2011 at 16:33
  • Heat does not pick up referenced assemblies.
    – tofutim
    Apr 24, 2012 at 2:16
  • What are some good examples of using T4 to generate the WXS file?
    – tofutim
    Apr 24, 2012 at 2:17
12
votes

Using Heat.exe to smash face and inflict "Epic Pwnage" on painfully large installs

Expanding on Si's and Robert-P's answers about heat.

Translation: (Using heat to avoid typing individual files into the project by hand and for automating builds for an overall easier process.)

WiX 2.0 Heat Syntax detailed

For newer versions (not all that different from older versions but there are potentially annoying syntax changes....) go to the directory Heat is in from the cmd.exe and just type in heat but I have a example one right here for help with newer versions if needed.

Adding the following to your Build Event in visual studio 2010.
(Right Click Project->Properties ->Build Events-> Pre-Build Events)

$(WIX)bin\heat.exe" dir "$(EnviromentVariable)" -cg GroupVariable -gg -scom -sreg -sfrag - srd -dr INSTALLLOCATION -var env.LogicPath -out "$(FragmentDir)\FileName.wxs

-gg 

Generates Guids when heat is run(as in when you execute the command above)

-scom 

Dont grab "COM files"

-sreg 

Dont grab "Registry Files"

-sfrag 

Dont grab "Fragments"

-srd 

Dont grab the "root Dir"

dir

dir indicates you want Heat to look in a folder

"$(EnviromentVariable)"

The name of the variable you would add to the Preprocessor variables in the (Right click project, Go to properties) project properties->Build section where it says Define preprocessor variables (assumes visual studio 2010)

Example:
EnviromentVariable=C:\Project\bin\Debug;
No double quotes but end with a semicolon

-cg GroupVariable 

The ComponentGroup that will be referenced from the fragment created to the main wxs file

FragmentDir

The fragment directory where the output wxs fragment will be stored

FileName.wxs

The the name of the file

Full tutorial here, So freakin helpful

Part 1 Part 2

1
9
votes

Including COM Objects:

heat generates all most (if not all) the registry entries and other configuration needed for them. Rejoice!

Including Managed COM Objects (aka, .NET or C# COM objects)

Using heat on a managed COM object will give you an almost complete wix document.

If you don't need the library available in the GAC (ie, globally available: MOST of the time you do not need this with your .NET assemblies anyway - you've probably done something wrong at this point if it's not intended to be a shared library) you will want to make sure to update the CodeBase registry key to be set to [#ComponentName]. If you ARE planning on installing it to the GAC (eg, you've made some new awesome common library that everyone will want to use) you must remove this entry, and add two new attributes to the File element: Assembly and KeyPath. Assembly should be set to ".net" and KeyPath should be set to "yes".

However, some environments (especially anything with managed memory such as scripting languages) will need access to the Typelib as well. Make sure to run heat on your typelib and include it. heat will generate all the needed registry keys. How cool is that?

8
votes

Installing to C:\ProductName

Some applications need to be installed to C:\ProductName or something similar, but 99.9% (if not 100%) of the examples in the net install to C:\Program Files\CompanyName\ProductName.

The following code can be used to set the TARGETDIR property to the root of the C: drive (taken from the WiX-users list):

<CustomAction Id="AssignTargetDir" Property="TARGETDIR" Value="C:\" Execute="firstSequence" />
<InstallUISequence>
    <Custom Action="AssignTargetDir" Before="CostInitialize">TARGETDIR=""</Custom>
</InstallUISequence>
<InstallExecuteSequence>
    <Custom Action="AssignTargetDir" Before="CostInitialize">TARGETDIR=""</Custom>
</InstallExecuteSequence>

NOTE: By default, TARGETDIR does not point to C:\! It rather points to ROOTDRIVE which in turn points to the root of the drive with the most free space (see here) - and this is not necessarily the C: drive. There might be another hard drive, partition, or USB drive!

Then, somewhere below your <Product ...> tag, you need the following directory tags as usual:

<Directory Id="TARGETDIR" Name="SourceDir">
    <Directory Id="APPLICATIONFOLDER" Name="$(var.ProductName)">
        <!-- your content goes here... -->
    </Directory>
</Directory>
2
  • Wouldn't it be simpler to just install to WindowsVolume?
    – Wim Coenen
    Aug 18, 2010 at 14:45
  • 1
    Yes, but you would have to use a workaround because the WindowsVolume property may not be used as a Directory (compiler gives an error/warning), as pointed out here and here. Personally, I find that workaround confusing.
    – gehho
    Aug 19, 2010 at 6:33
7
votes

Environmental Variables

When compiling your Wxs documents to wixobj code, you can make use of environmental variables to determine various information. For example, lets say you want to change which files get included in a project. Lets say you have an environmental variable called RELEASE_MODE, that you set right before you build your MSI (either with a script or manually, it doesn't matter) In your wix source, you can do something like:

<define FILESOURCE = c:\source\output\bin\$(env.RELEASE_MODE) >

and then later in your code, use it in place to on the fly change your wxs document, eg:

<Icon Id="myicon.ico" SourceFile="$(var.FILESOURCE)" />
2
  • 1
    Also compilation variables such as $(Configuration) and $(Platform) are available. Also a bunch more at msdn.microsoft.com/en-us/library/aa302186.aspx
    – si618
    Apr 10, 2009 at 0:16
  • 1
    @Si - Sometime before today, that link is no longer active. I couldn't find the latest one.
    – Peter M
    Jul 6, 2010 at 14:58
7
votes

Using the RobM special "Remember Property" pattern

http://robmensching.com/blog/posts/2010/5/2/The-WiX-toolsets-Remember-Property-pattern

7
votes

Creating Custom Action for WIX written in managed code (C#) without Votive

http://www.codeproject.com/KB/install/wixcustomaction.aspx

7
votes

Editing Dialogs

One good ability to edit dialogs is using SharpDevelop in a version 4.0.1.7090 (or higher). With help of this tool a standalone dialog (wxs files from WiX sources like e.g. InstallDirDlg.wxs) can be opened, previewed and edited in Design view.

1
  • Awesome, didn't know SharpDevelop supported this. Sep 3, 2012 at 13:54
6
votes

Setting the IIS enable32BitAppOnWin64 flag http://trycatchfail.com/blog/post/WiX-Snippet-change-enable32BitAppOnWin64.aspx

<InstallExecuteSequence>
   <RemoveExistingProducts After="InstallFinalize" />
   <Custom Action="ConfigureAppPool" After="InstallFinalize" >
     <![CDATA[NOT Installed AND VersionNT64 >= 600]]>         
   </Custom>
</InstallExecuteSequence>

<CustomAction Id="ConfigureAppPool" Return="check" Directory="TARGETDIR" ExeCommand="[SystemFolder]inetsrv\appcmd set apppool /apppool.name:[APPPOOLNAME] /enable32BitAppOnWin64:false" />
5
votes

Modify the "Ready to install?" dialog (aka VerifyReadyDlg) to provide a summary of choices made.

It looks like this:
alt text http://i46.tinypic.com/s4th7t.jpg

Do this with a Javascript CustomAction:


Javascript code:

// http://msdn.microsoft.com/en-us/library/aa372516(VS.85).aspx
var MsiViewModify = 
    {
        Refresh          : 0,
        Insert           : 1,
        Update           : 2,
        Assign           : 3,
        Replace          : 4,
        Merge            : 5,
        Delete           : 6,
        InsertTemporary  : 7,   // cannot permanently modify the MSI during install
        Validate         : 8,
        ValidateNew      : 9,
        ValidateField    : 10,
        ValidateDelete   : 11
    };


// http://msdn.microsoft.com/en-us/library/sfw6660x(VS.85).aspx
var Buttons = 
    {
        OkOnly           : 0,
        OkCancel         : 1,
        AbortRetryIgnore : 2,
        YesNoCancel      : 3
    };

var Icons= 
    {
        Critical         : 16,
        Question         : 32,
        Exclamation      : 48,
        Information      : 64
    }

var MsgKind =
    {
        Error            : 0x01000000,
        Warning          : 0x02000000,
        User             : 0x03000000,
        Log              : 0x04000000
    };

// http://msdn.microsoft.com/en-us/library/aa371254(VS.85).aspx
var MsiActionStatus = 
    {
        None             : 0,
        Ok               : 1, // success
        Cancel           : 2,
        Abort            : 3,
        Retry            : 4, // aka suspend?
        Ignore           : 5  // skip remaining actions; this is not an error.
    };

function UpdateReadyDialog_CA(sitename)
{
    try 
    {
        // can retrieve properties from the install session like this:
        var selectedWebSiteId = Session.Property("MSI_PROPERTY_HERE");

        // can retrieve requested feature install state like this:
        var fInstallRequested   = Session.FeatureRequestState("F.FeatureName");

        var text1 = "This is line 1 of text in the VerifyReadyDlg";

        var text2 = "This is the second line of custom text";

        var controlView     = Session.Database.OpenView("SELECT * FROM Control");
        controlView.Execute();

        var rec             = Session.Installer.CreateRecord(12);
        rec.StringData(1)   = "VerifyReadyDlg";    // Dialog_
        rec.StringData(2)   = "CustomVerifyText1"; // Control - can be any name
        rec.StringData(3)   = "Text";              // Type
        rec.IntegerData(4)  = 25;                  // X
        rec.IntegerData(5)  = 60;                  // Y
        rec.IntegerData(6)  = 320;                 // Width
        rec.IntegerData(7)  = 85;                  // Height
        rec.IntegerData(8)  = 2;                   // Attributes
        rec.StringData(9)   = "";                  // Property
        rec.StringData(10)  = vText1;              // Text
        rec.StringData(11)  = "";                  // Control_Next
        rec.StringData(12)  = "";                  // Help
        controlView.Modify(MsiViewModify.InsertTemporary, rec);

        rec                 = Session.Installer.CreateRecord(12);
        rec.StringData(1)   = "VerifyReadyDlg";    // Dialog_
        rec.StringData(2)   = "CustomVerifyText2"; // Control - any unique name
        rec.StringData(3)   = "Text";              // Type
        rec.IntegerData(4)  = 25;                  // X
        rec.IntegerData(5)  = 160;                 // Y
        rec.IntegerData(6)  = 320;                 // Width
        rec.IntegerData(7)  = 65;                  // Height
        rec.IntegerData(8)  = 2;                   // Attributes
        rec.StringData(9)   = "";                  // Property
        rec.StringData(10)  = text2;               // Text
        rec.StringData(11)  = "";                  // Control_Next
        rec.StringData(12)  = "";                  // Help
        controlView.Modify(MsiViewModify.InsertTemporary, rec);

        controlView.Close();
    }
    catch (exc1)
    {
        Session.Property("CA_EXCEPTION") = exc1.message ;
        LogException("UpdatePropsWithSelectedWebSite", exc1);
        return MsiActionStatus.Abort;
    }
    return MsiActionStatus.Ok;
}


function LogException(loc, exc)
{
    var record = Session.Installer.CreateRecord(0);
    record.StringData(0) = "Exception {" + loc + "}: " + exc.number + " : " + exc.message;
    Session.Message(MsgKind.Error + Icons.Critical + Buttons.btnOkOnly, record);
}

Declare the Javascript CA:

<Fragment>
  <Binary Id="IisScript_CA" SourceFile="CustomActions.js" />

  <CustomAction Id="CA.UpdateReadyDialog"
              BinaryKey="IisScript_CA"
              JScriptCall="UpdateReadyDialog_CA"
              Execute="immediate"
              Return="check" />
</Fragment>

Attach the CA to a button. In this example, the CA is fired when Next is clicked from the CustomizeDlg:

<UI ...>
  <Publish Dialog="CustomizeDlg" Control="Next" Event="DoAction" 
           Value="CA.UpdateReadyDialog" Order="1"/>
</UI>

Related SO Question: How can I set, at runtime, the text to be displayed in VerifyReadyDlg?

1
  • Surely shouldn't this be JScript the windows scripting language rather that JavaScript the DHTML scripting language. Possibly a bit pedantic, but could be a bit confusing to some people. May 16, 2011 at 18:07
5
votes

Put Components which may be patched individually inside their own Fragments

It goes for both making product installers and patches that if you include any component in a fragment, you must include all of the components in that fragment. In the case of building an installer, if you miss any component references, you'll get a linking error from light.exe. However, when you make a patch, if you include a single component reference in a fragment, then all changed components from that fragment will show up in your patch.

like this:

<Fragment>
    <DirectoryRef Id="SampleProductFolder">
        <Component Id="SampleComponent1" Guid="{C28843DA-EF08-41CC-BA75-D2B99D8A1983}" DiskId="1">
            <File Id="SampleFile1" Source=".\$(var.Version)f\Sample1.txt" />
        </Component>
    </DirectoryRef>
</Fragment>

<Fragment>
    <DirectoryRef Id="SampleProductFolder">
        <Component Id="SampleComponent2" Guid="{6CEA5599-E7B0-4D65-93AA-0F2F64402B22}" DiskId="1">
           <File Id="SampleFile2" Source=".\$(var.Version)f\Sample2.txt" />
        </Component>
    </DirectoryRef>
</Fragment>

<Fragment>
    <DirectoryRef Id="SampleProductFolder">
        <Component Id="SampleComponent3" Guid="{4030BAC9-FAB3-426B-8D1E-DC1E2F72C2FC}" DiskId="1">
           <File Id="SampleFile3" Source=".\$(var.Version)f\Sample3.txt" />
        </Component>
    </DirectoryRef>
</Fragment>

instead of this:

<Fragment>
    <DirectoryRef Id="SampleProductFolder">
        <Component Id="SampleComponent1" Guid="{C28843DA-EF08-41CC-BA75-D2B99D8A1983}" DiskId="1">
            <File Id="SampleFile1" Source=".\$(var.Version)\Sample1.txt" />
        </Component>

        <Component Id="SampleComponent2" Guid="{6CEA5599-E7B0-4D65-93AA-0F2F64402B22}" DiskId="1">
           <File Id="SampleFile2" Source=".\$(var.Version)\Sample2.txt" />
        </Component>

        <Component Id="SampleComponent3" Guid="{4030BAC9-FAB3-426B-8D1E-DC1E2F72C2FC}" DiskId="1">
           <File Id="SampleFile3" Source=".\$(var.Version)\Sample3.txt" />
        </Component>
    </DirectoryRef>
</Fragment>

Also, when patching using the "Using Purely WiX" topic from the WiX.chm help file, using this procedure to generate the patch:

torch.exe -p -xi 1.0\product.wixpdb 1.1\product.wixpdb -out patch\diff.wixmst
candle.exe patch.wxs
light.exe patch.wixobj -out patch\patch.wixmsp
pyro.exe patch\patch.wixmsp -out patch\patch.msp -t RTM patch\diff.wixmst

it's not enough to just have the 1.1 version of the product.wixpdb built using the components in separate fragments. So be sure to correctly fragment your product before shipping.

5
votes

Printing EULA from Wix3.0 and later

1) When you compile your wix source code, the light.exe must reference the WixUIExtension.dll in command line. Use the command line switch -ext for this.

2) If when you add the reference to the WixUIExtension.dll, your project fails to compile, this is most likely because of clashes of Dialog IDs, i.e. your project was using the same IDs of dialogs as some standard dialogs in WixUIExtension.dll, give different IDs to your dialogs. This is quite common problem.

3) Your license dialog must have ScrollableText control with the id "LicenseText". Wix searches for exactly this name of control when it prints.

<Control Id="LicenseText" Type="ScrollableText" X="20" Y="60" Width="330" Height="160" Sunken="yes" TabSkip="no">
    <Text SourceFile="License.rtf" />
</Control>

and a PushButton which refers to the custom action

<Control Type="PushButton" Id="PrintButton" Width="57" Height="17" X="19" Y="244" Text="Print">
    <Publish Event="DoAction" Value="PrintEula">1</Publish>
</Control>

4) Define CustomAction with the Id="PrintEula" like this:

<CustomAction Id="PrintEula" BinaryKey="WixUIWixca" DllEntry="PrintEula" Return="ignore" Execute="immediate" />

Note: BinaryKey is different in Wix3.0 comparing to Wix2.0 and must be exactly "WixUIWixca" (case sensitive).

When user presses the button he/she will be presented with the standard Select Printer Dialog and will be able to print from there.

5
votes
  • We display the product version somewhere (tiny) in the first screen of the GUI. Because people tend to make mistakes in picking the right version every time. (And keep us developers searching for ages..)

  • We've set up TFSBuild to also generate transforms (.mst files) with the configuration for our different environments. (We know about all environments we need to deploy to).

Since the original weblog post by Grant Holliday is down, I copy pasted its contents here:


MSBuild task to generate MSI Transform files from XMLMarch 11 2008

In my previous post I described how you can use MSI Transform (*.mst) files to separate environment-specific configuration settings from a generic MSI package.

Although this provides a level of flexibility in your configuration, there are two down-sides of Transform files:

  1. They’re a binary format
  2. You can’t “edit” or “view” a transform file. You have to apply it or re-create it to see what changes it includes.

Fortunately we can use the Microsoft Windows Installer Object Library (c:windowssystem32msi.dll) to open MSI “databases” and create transform files.

Credits go again to Alex Shevchuk – From MSI to WiX – Part 7 – Customising installation using Transforms for showing us how to achieve this with VbScript. Essentially all I’ve done is taken Alex’s example and using Interop.WindowsInstaller.dll I’ve implemented an MSBuild task. The MSBuild Task

Download the source code & example transforms.xml here (~7Kb Zipped VS2008 Solution)


1
  • 2
    We redefine WelcomeDlgTitle in my localizations file - works great! <String Id="WelcomeDlgTitle">{\WixUI_Font_Bigger}Welcome to the [ProductName] [ProductVersion] Setup Wizard</String> Aug 20, 2009 at 2:34
5
votes

Before deploying an install package I always control the content of it.

It's just a simple call at the command line (according to Terrences post) open command line and enter

msiexec /a Package.msi /qb TARGETDIR="%CD%\Extract" /l*vx "%CD\install.log%"

This will extract package contents to an subdir 'Extract' with the current path.

4
votes

Instead of ORCA use InstEd which is a good tool for viewing MSI tables. Also it has the ability to diff two packages by Transform -> Compare To...

Additionally a Plus version with additional functionality is available. But also the free version offers a good alternative for Orca.

4
votes

Registering .NET assemblies for COM Interop with x86/x64 compatibility

NB This fragment is essentially the same as REGASM Assembly.dll /codebase

A couple of things are going on in this sample so here's the code and I'll explain it afterwards...

  <Wix xmlns="http://schemas.microsoft.com/wix/2006/wi">
  <?include $(sys.CURRENTDIR)\Config.wxi?>
  <?if $(var.Win64) ?>
  <?define CLSIDRoots = "CLSID;Wow6432Node\CLSID"?>
  <?else ?>
  <?define CLSIDRoots = "CLSID"?>
  <?endif?>
  <!-- ASCOM Driver Assembly with related COM registrations -->
  <Fragment>
    <DirectoryRef Id="INSTALLLOCATION" />
  </Fragment>
  <Fragment>
    <ComponentGroup Id="cgAscomDriver">
      <Component Id="cmpAscomDriver" Directory="INSTALLLOCATION" Guid="{0267031F-991D-4D88-A748-00EC6604171E}">
        <File Id="filDriverAssembly" Source="$(var.TiGra.Astronomy.AWRDriveSystem.TargetPath)" KeyPath="yes" Vital="yes" Assembly=".net" AssemblyApplication="filDriverAssembly"  />
        <RegistryKey Root="HKCR" Key="$(var.DriverId)"  Action="createAndRemoveOnUninstall">
          <RegistryValue Type="string" Value="$(var.DriverTypeName)"/>
          <RegistryKey Key="CLSID">
            <RegistryValue Type="string" Value="$(var.DriverGuid)" />
          </RegistryKey>
        </RegistryKey>
        <?foreach CLSID in $(var.CLSIDRoots) ?>
        <RegistryKey Root="HKCR" Key="$(var.CLSID)" Action="none">
          <RegistryKey Key="$(var.DriverGuid)" Action="createAndRemoveOnUninstall">
            <RegistryValue Type="string" Value="$(var.DriverTypeName)"/>
            <RegistryKey Key="InprocServer32">
              <RegistryValue Type="string" Value="mscoree.dll" />
              <RegistryValue Type="string" Name="ThreadingModel" Value="Both"/>
              <RegistryValue Type="string" Name="Class" Value="$(var.DriverTypeName)"/>
              <RegistryValue Type="string" Name="Assembly" Value="!(bind.assemblyFullname.filDriverAssembly)" />
              <RegistryValue Type="string" Name="RuntimeVersion" Value="v2.0.50727"/>
              <RegistryValue Type="string" Name="CodeBase" Value="file:///[#filDriverAssembly]" />
              <RegistryKey Key="!(bind.fileVersion.filDriverAssembly)" >
                <RegistryValue Type="string" Name="Class" Value="$(var.DriverTypeName)"/>
                <RegistryValue Type="string" Name="Assembly" Value="!(bind.assemblyFullname.filDriverAssembly)" />
                <RegistryValue Type="string" Name="RuntimeVersion" Value="v2.0.50727"/>
                <RegistryValue Type="string" Name="CodeBase" Value="file:///[#filDriverAssembly]" />
              </RegistryKey>
            </RegistryKey>
            <RegistryKey Key="ProgId" Action="createAndRemoveOnUninstall">
              <RegistryValue Type="string" Value="$(var.DriverId)" />
            </RegistryKey>
            <RegistryKey Key="Implemented Categories" Action="createAndRemoveOnUninstall" >
              <RegistryKey Key="{62C8FE65-4EBB-45e7-B440-6E39B2CDBF29}" Action="createAndRemoveOnUninstall" />
            </RegistryKey>
          </RegistryKey>
        </RegistryKey>
        <?endforeach?>
      </Component>
    </ComponentGroup>
  </Fragment>
</Wix>

If you were wondering, this is actually for an ASCOM Telescope Driver.

First, I took advice from above and created some platforma variables in a seperate file, you can see those scattered through the XML.

The if-then-else part near the top deals with x86 vs x64 compatibility. My assembly targets 'Any CPU' so on an x64 system, I need to register it twice, once in the 64-bit registry and once in the 32-bit Wow6432Node areas. The if-then-else sets me up for this, the values are used in a foreach loop later on. This way, I only have to author the registry keys once (DRY principle).

The file element specifies the actual assembly dll being installed and registered:

<File Id="filDriverAssembly" Source="$(var.TiGra.Astronomy.AWRDriveSystem.TargetPath)" KeyPath="yes" Vital="yes" Assembly=".net" AssemblyApplication="filDriverAssembly"  />

Nothing revolutionary, but notice the Assembly=".net" - this attribute alone would cause the assembly to be put into the GAC, which is NOT what I wanted. Using the AssemblyApplication attribute to point back to itself is simply a way of stopping Wix putting the file into the GAC. Now that Wix knows it's a .net assembly, though, it lets me use certain binder variables within my XML, such as the !(bind.assemblyFullname.filDriverAssembly) to get the assembly full name.

3
votes

Set the DISABLEADVTSHORTCUTS property to force all advertised shortcuts in your installer to become regular shortcuts, and you don't need to include a dummy reg key to be used as the keypath.

<Property Id="DISABLEADVTSHORTCUTS" Value="1"/>

I think Windows Installer 4.0 or higher is a requirement.

2
votes

It's a nice structure but based on my experience I wonder how you address these conditions:

A. Your installs all appear to land in the same destination. If a user needs to install all 3 versions at once will your process allow this. Can they unambiguously tell which version of every executable they are triggering?

B. How do you handle new files that exist in TEST and/or TRAINING but not yet in LIVE?

2
  • Hi Blaine, A. No they don't. InstallName is in Config.wxi which is the only file not referenced by svn:externals. So this is unique for each install, i.e. each product. That's also why we modify Guids for each version. B. GOTO A. :) They are separate MSI's with their own UpgradeCode.
    – si618
    Feb 23, 2009 at 17:14
  • 1
    by the way, I understand why you answered my question with a question, but once you get enough rep points, please move your question to the answer comments, otherwise thread will be difficult to follow.
    – si618
    Feb 23, 2009 at 17:17
2
votes

Here's a way to help large web projects verify that the number of deployed files matches the number of files built into an MSI (or merge module). I've just run the custom MSBuild task against our main application (still in development) and it picked up quite a few missing files, mostly images, but a few javascript files had slipped through to!

This approach (peeking into File table of MSI by hooking into AfterBuild target of WiX project) could work for other application types where you have access to a complete list of expected files.

2
votes

Performing a forced reinstall when an install doesn't allow uninstall or reinstall and doesn't roll back.

VBscript script used for overriding an install that isn't uninstalling for whatever reason..

Dim objShell
set objShell = wscript.createObject("wscript.shell")

iReturn = objShell.Run("CMD /K MsiExec.exe /I ""C:\Users\TheUser\Documents\Visual Studio 2010\Projects\InstallationTarget\HelloInstaller\bin\Debug\HelloInstaller.msi"" REINSTALLMODE=vomus REINSTALL=ALL",,True)
2
votes

Create a UI that has a custom action that will set a variable and the UI will disable/enable the next button (or similar) based upon the variable set in the custom action.

Not as straight-forward as you would think, not too difficult just not documented anywhere!

Wix Interactions with Conditions, Properties & Custom Actions

Not the answer you're looking for? Browse other questions tagged or ask your own question.