1

I've got error message :

Requested registry access is denied

when trying to write into registery keys with turned on UAC :

RegistryKey.OpenRemoteBaseKey(Microsoft.Win32.RegistryHive.LocalMachine, "")
tawkey.OpenSubKey(x, true).SetValue(X, V, RegistryValueKind.DWord)

Must I run "subinacl /subkeyreg HKEY_LOCAL_MACHINE\PathToMyKeys... /grant=user=f" during My software installation ? Or there is some other way to have access to my registry keys ?

Thank you.

5
  • You want to do this on a remote machine? Aug 10, 2011 at 6:42
  • not - on my own machine.
    – cnd
    Aug 10, 2011 at 6:45
  • If its alocal machine, why use OpenRemoteBaseKey??
    – Zenwalker
    Aug 10, 2011 at 6:54
  • just... do you recommend to use Microsoft.Win32.Registry.LocalMachine.OpenSubKey ? sadly it shows same error.
    – cnd
    Aug 10, 2011 at 7:05
  • @nCdy Microsoft.Win32.Registry.LocalMachine.OpenSubKey is definitely better but the problem you have is that standard users do not have write access to HKLM. You won't get around that by using different registry access APIs. They will all fail in the same way. Aug 10, 2011 at 7:41

1 Answer 1

6

If you wish to write to keys under HKLM, you need an elevated process. This is achieved by setting requestedExecutionLevel to requireAdministrator in the application's manifest.

Making this change means that your application will present a UAC elevation dialog every time it runs. This will no doubt be irritating and so here are some options of avoiding that irritation:

  1. Write to somewhere other than HLKM where standard users have write access.
  2. Perform the writes to HLKM in your install program.
  3. Arrange that you elevate on demand if writing to HLKM is only needed for occasionally used functionality in your program.

Option 3 needs a little elaboration. You can't elevate a process once it has started. You can only elevate at process start time. So in order to implement option 3, you need that functionality to exist in a separate process or out of process COM server. If you go down this route remember to include the shield icon on any UI element that results in a UAC dialog.

2
  • 1
    got strange message : ClickOnce does not support the request execution level 'requireAdministrator'
    – cnd
    Aug 10, 2011 at 6:59
  • 2
    Can you explain where ClickOnce comes into this. I didn't see that in your question. FWIW I understand that ClickOnce and UAC elevation are not meant to go together: geektieguy.com/2007/08/25/… Aug 10, 2011 at 7:06

Your Answer

By clicking “Post Your Answer”, you agree to our terms of service and acknowledge you have read our privacy policy.

Not the answer you're looking for? Browse other questions tagged or ask your own question.