Tag Info

Hot answers tagged

483

AssemblyVersion Where other assemblies that reference your assembly will look. If this number changes, other assemblies have to update their references to your assembly! The AssemblyVersion is required. I use the format: major.minor. This would result in: [assembly: AssemblyVersion("1.0")] AssemblyFileVersion Used for deployment. You can increase this ...


320

Here is a blog post I recently wrote that delves into the details of assembly versioning... Versioning of assemblies in .NET can be a confusing prospect given that there are currently at least three ways to specify a version for your assembly. Here are the three main version-related assembly attributes: // Assembly mscorlib, Version 2.0.0.0 [assembly: ...


319

Add the following values to HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Fusion Add: DWORD ForceLog set value to 1 DWORD LogFailures set value to 1 DWORD LogResourceBinds set value to 1 String LogPath set value to folder for logs (e.g. C:\FusionLog\) Make sure you include the backslash after the folder name and that the Folder exists. You need to restart the ...


304

See my comment above asking for clarification on what you really want. Hopefully this is it: Assembly assembly = Assembly.GetExecutingAssembly(); FileVersionInfo fvi = FileVersionInfo.GetVersionInfo(assembly.Location); string version = fvi.FileVersion;


230

There are few reasons for removing unused using(s)/namespaces, besides coding preference: removing the unused using clauses in a project, can make the compilation faster because the compiler has fewer namespaces to look-up types to resolve. (this is especially true for C# 3.0 because of extension methods, where the compiler must search all namespaces for ...


140

You can use the CorFlags CLI tool (for instance, C:\Program Files\Microsoft SDKs\Windows\v7.0\Bin\CorFlags.exe) to determine the status of an assembly, based on its output and opening an assembly as a binary asset you should be able to determine where you need to seek to determine if the 32BIT flag is set to 1 (x86) or 0 (Any CPU or x64, depending on PE): ...


120

We're using a global file called GlobalAssemblyInfo.cs and a local one called AssemblyInfo.cs. The global file contains the following attributes: [assembly: AssemblyProduct("Your Product Name")] [assembly: AssemblyCompany("Your Company")] [assembly: AssemblyCopyright("Copyright © 2008 ...")] [assembly: AssemblyTrademark("Your Trademark - if applicable")] ...


117

Getting loaded assemblies for the current AppDomain: var loadedAssemblies = AppDomain.CurrentDomain.GetAssemblies(); Getting the assemblies referenced by another assembly: var referencedAssemblies = someAssembly.GetReferencedAssemblies(); Note that if assembly A references assembly B and assembly A is loaded, that does not imply that assembly B is also ...


113

Yes. You need to use Assembly.LoadFrom to load the assembly into memory, then you can use Activator.CreateInstance to create an instance of your preferred type. You'll need to look the type up first using reflection. Here is a simple example: Assembly assembly = Assembly.LoadFrom("MyNice.dll"); Type type = assembly.GetType("MyType"); object ...


101

It won't change anything when your program runs. Everything that's needed is loaded on demand. So even if you have that using statement, unless you actually use a type in that namespace / assembly, the assembly that using statement is correlated to won't be loaded. Mainly, it's just to clean up for personal preference.


92

To avoid this error you could either: Load the assembly dynamically, or sign the third-party assembly. You will find instructions on signing third-party assemblies in .NET-fu: Signing an Unsigned Assembly (Without Delay Signing).


86

If you have the Windows SDK installed on your machine, you'll find the "Fusion Log Viewer" under Microsoft SDK\Tools (just type "Fusion" in the start menu on Vista or Windows 7/8). Launch it, click the Settings button, and select "Log bind failure" or "Log all binds". If these buttons are disabled, go back to the start menu, right-click the Log Viewer, and ...


83

Just for clarification, CorFlags.exe is part of the .NET Framework SDK. I have the development tools on my machine, and the simplest way for me determine whether a DLL is 32-bit only is to: Open the Visual Studio Command Prompt (In Windows: menu Start/Programs/Microsoft Visual Studio/Visual Studio Tools/Visual Studio 2008 Command Prompt) CD to the ...


82

Look at System.Reflection.AssemblyName.GetAssemblyName(string assemblyFile) You can examine assembly metadata from the returned AssemblyName instance: [36] C:\> [reflection.assemblyname]::GetAssemblyName("${pwd}\Microsoft.GLEE.dll") | fl Name : Microsoft.GLEE Version : 1.0.0.0 CultureInfo : CodeBase ...


81

I have used the advice from this article to get an assembly from the GAC. Get DLL Out of The GAC DLLs once deployed in GAC (normally located at c:\windows\assembly) can’t be viewed or used as a normal DLL file. They can’t be directly referenced from VS project. Developers usually keep a copy of the original DLL file and refer to it ...


75

Referencing an external ResourceDictionary (XAML File): <Application.Resources> <ResourceDictionary Source="MyResources.xaml" /> </Application.Resources> Referencing an external ResourceDictionary (DLL): <Application.Resources> <ResourceDictionary Source="/MyExternalAssembly;component/MyResources.xaml" /> ...


66

The method described here is very easy: http://andreasglaser.net/post/2008/08/05/Extract-assembly-from-Global-Assembly-Cache-(GAC)-with-network-drive-mapping.aspx Summary from Article: Map a Network Drive (Explorer -> Tools) Map to \servername\folder (\\YourServer\C$\Windows\Assembly) No need for sharing if you are the Administrator Browse to the drive ...


66

For people that cant find "System.Web" at .Net References, this might be the answer: "you need to right-click the project -> properties -> then change the "Target framework" which will probably be ".NET Framework 4 Client Profile" to just ".NET Framework 4". The answer was given by Tinister (thanks) as a reply to a previuos post. But I thought it was a ...


65

System.Data is a namespace, System.Data.DLL (the file) is an assembly. A namespace is a logical grouping of types (mostly to avoid name collisions). An assembly can contain types in multiple namespaces (System.DLL contains a few...), and a single namespace can be spread across assemblies (e.g. System.Threading).


62

In IIS 6, go to the Application Pools section, and right-click > Properties on the pool which hosts the ASP.NET application in question. Go to the Performance tab and uncheck "Shutdown worker processes after being idle for:" In IIS 7, go to the Connections pane and find Application Pools, and select Advanced Settings for the pool which hosts your ...


61

cshtml/vbhtml is dynamic compile to assembly. @typeof(YourApplicationNamespace.MvcApplication).Assembly.GetName().Version how about this?


58

Sounds like you could use the AppDomain.AssemblyResolve event and manually load the dependencies from your DLL directory. Edit (from the comment): AppDomain currentDomain = AppDomain.CurrentDomain; currentDomain.AssemblyResolve += new ResolveEventHandler(LoadFromSameFolder); static Assembly LoadFromSameFolder(object sender, ResolveEventArgs args) { ...


55

I work on the CLR/BCL team and just answered your email. Here it is pasted below: Jared's answer on Stack Overflow is right on. mscorlib.dll is tightly bound to the CLR for the reasons he mentions. Note that mscorlib.dll itself doesn't contain any native code (as Scott suggests), but there are many places where it needs to call directly ...


54

That's because you use the .NET 4.0 version of gacutil.exe. It stores the assembly in a different GAC, the one in c:\windows\microsoft.net\assembly. Where all .NET 4.0 assemblies are stored. There is no shell extension handler for that one, the folders are visible as-is. You can have a look-see with Windows Explorer, .you'll see the internal structure of ...


52

I had the same error message while ago and it was caused due to missing ScriptManager. You may need to add ScriptManager to your aspx page. <asp:ScriptManager runat="server"></asp:ScriptManager> Or you can add ScriptManager dynamically at Page_Load event of code behind. if (ScriptManager.GetCurrent(Page) == null) { ...


50

In most cases: more than fast enough. For example, if you are using this to create a DAL wrapper object, the time taken to create the object via reflection will be miniscule compared to the time it needs to connect to a network. So optimising this would be a waste of time. If you are using reflection in a tight loop, there are tricks to improve it: ...


48

Question: When should I deploy my assemblies into the GAC? Answer: Never Actual, honest, Real Answer: Hardly Ever Discussion Only drop things into the GAC when multiple apps on the machine will use the assembly, and when the assembly is foundational (likely to be used by multiple apps), when it is signed, and when you expect to almost never ...


48

Why would the previous author have signed the assemblies in this way? No idea, maybe he wanted all his assemblies to be signed with the same key. Is signing assemblies necessary and what would be wrong with not signing it? No, it is not necessary but it is a mechanism allowing you to ensure the authenticity of an assembly. It allows you to ensure ...


48

Try adding your <loadFromRemoteSources enabled="true" /> to C:\[Visual Studio 2010 Install Dir]\Common7\IDE\devenv.exe.config directly below <runtime> and see if that helps :)



Only top voted, non community-wiki answers of a minimum length are eligible