Tag Info

New answers tagged

0

I have written this code but clear screen subroutine is not working. [org 0x0100] jmp start hr db 0 min db 0 sec db 0 printnum: push bp mov bp, sp push es push ax push bx push cx push dx push di mov ax, 0xb800 mov es, ax mov ax, [bp+4] ...


0

A bit of necrophilia; hopefully your assembly skills have improved in the meantime. But just in case... To quote @Alexey Frunze, "You need to pay attention to what you're doing". In addition to the mistakes detailed in the other answers, here are some of my observations: Your emulator is too kind Your code appears to be a bootloader. You assume the ...


0

If you have changed a board, and also not all BIOS codes are actually pre-entered. In that case it is necessary to boot into the BIOS of a machine with that issue, and enter it manually (from reading it off of the hardware itself.) In other words, if the machine is not very old, the response you are getting is the default response when no value is set ...


1

mrjoltcola's answer is great and applicable to Legacy MBR-style bootloaders. A few notes on UEFI booting: unlike the MBR system which is device-specific, UEFI uses boot paths: a fully-qualified path to any file that is an OS bootloader there is no practical limitation in UEFI on the number of OS bootloaders you can configure on your system--just add the ...


2

Bootloaders can exist in multiple places. There is one MBR (Master Boot Record) but there are multiple partitions. Each partition can have a bootloader in its Volume Boot Record (VBR) - the first sector of a bootable partition. You can have a bootloader on the MBR and/or within a VBR, so the MBR will chain to the secondary bootloader in the VBR. This is how ...


2

My experience is with AVR, so your mileage may vary. Typically, the program counter starts at 0, so the first instruction is at the first position in the flash memory. This is also the location of vector table, or addresses where the processor is hardwired to jump to when interrupts of various types occur. These addresses are only a few bytes apart, ...


1

For something like this you can think of hardware like software just parallel. After reset (actually during) items like the starting address and states for the state machines are initialized to the value the author wanted. Then it starts clocking after reset and walking through the code which for a simplistic case might be address of zero state is fetch, ...


0

You Can Use This Code: mov si,msg_text call print_colored print_colored: .loop: lodsb cmp al,0 je .done inc bl mov ah,0x0E Int 0x10 jmp .loop .done: ret It makes your String colored but not for your choice.