Tag Info

New answers tagged

0

If the printer is networked, it most likely can accept documents over a TCP connection. I know HP printers can. You send some control codes, then the data. For example, a code that tells the printer the following byte stream is a PDF, then the binary PDF.


0

By default, it's set to ... C:\ProgramData\Microsoft\BAM\alerts


1

Its fully supported by Microsoft. For more details http://msdn.microsoft.com/en-us/biztalk/dd876606.aspx . Version 2.2 is also part of BizTalk 2013+ product installation itself.


2

Did you try using the local-name() function? For example: //*[local-name()='MCCI_IN000002UV01']/*[local-name()='versionCode']/@code


0

If you want to use Linq2Xml: var xDoc = XDocument.Load(filename); 1- Using XPath XmlNamespaceManager mgr = new XmlNamespaceManager(xDoc.CreateNavigator().NameTable); mgr.AddNamespace("hl7", "urn:hl7-org:v3"); var version = xDoc.XPathSelectElement("hl7:MCCI_IN000002UV01/hl7:versionCode", mgr); var code = version.Attribute("code").Value; 2- Using Linq ...


0

Most likely your Component 1 adding a XmlElement node with some invalid value e.g. adding empty value for complex type node (record node) (<Order><price></price></Order> adding empty value after <Order> and then <price> comes). If you are using a map to create Xml before message comes to even Component 1, it might be ...


0

I think there is a problem in your URL. what if you try to use in the utl the link to your sharepoint site and the name of your List as "Destination Folder URL". you can check this walkthrough


1

The two easiest options (IMO) would be: What I would do is: Create an Equal Functoid (1st condition being that "certain element" and 2nd condition being the text you would like to check it against) Create a Value Mapping Functoid and connect the Equal Functoid (that you just made) to it first and then connect it your scripting functoid. Now connect your ...


0

I also do not have BizTalk 2006/R2 installed. My suggestion is looking for the related stored procedure, which in my BizTalk 2013 installation, it looks like the edi_ResetX12Icn in BizTalkMsgBoxDb.


1

ZZ is not a Liaison specific qualifer. ZZ means mutually defined per the ANSI X12 standard. It's kind of a "catch all" where the trading partners can agree that ZZ will suit their needs because the other codes might not necessarily apply. It's used a lot of times in the ISA where a trading partner will arbitrarily make up their identifier instead of ...


1

First, make sure you want and need to do this. "Human Resource" and "Supply Chain" don't really sound like credible invoice types and you risk just annoying the trading partners with such a deviation. There are several hundred valid codes already. How exactly do you plan to use this? Maybe there is a better way, like the NTE segment which kind of a ...


1

Thanks Johns-305. I included the Message assignment shape before the send shape and used the SendMessage(FILE.ReceivedFileName) = "ABC.txt"; In the Send Port I used Filename as "%SourceFileName%". Now I get the filename as ABC.txt.pgp in the Send Port


1

What you are seeing is the expected behavior. If you are referring to this: https://code.msdn.microsoft.com/windowsdesktop/BizTalk-Sample-PGP-ebcbc8b2 or one of it's derivatives, it will internally modify FILE.ReceivedFileName to append .pgp if that property is set. So, if you use just %SourceFileName%, you will likely get the desired result. Otherwise, ...


0

Unfortunately I only have a BizTalk 2010 available here, so i'm not sure if this functionality is already present in BizTalk 2006/2006 R2. In BizTalk 2010 and 2009 you have the option to reset the ISA on the following party agreement (see image below). Do you have a similar option in BizTalk 2006 R2 in the party settings?


0

My question is If my application(A) and my MQ server is down after pushing the message to Biztalk Once the message is in the Queue, Application A no longer has control over the message. So if A crashes nothing will happen to the message pushed to the queue. What is the result if biztalk is down after owning the message? will it still hold the ...


0

You must first install the certificate on the computer running BizTalk Server. To do this you can try following these steps: On the windows start menu click 'Run', type mmc and press enter; A 'Console1' windows will apear. Click on the 'File' menu and then on 'Add/Remove Snap-in'; In the 'Add or Remove Snap-ins' dialog box, in the Available snap-ins list, ...


0

If application A successfully pushes the message to the queue, then crashes, the message is still in the queue. At that point, it doesn't matter what 'state' application A is in, the message is now owned by WMQ and will be delivered to destination. BizTalk will still read the message, completely unaware that application A may have crashed.


1

For now, there MIGHT be a workaround by setting the UseAmbientTransaction property to false. Off course, the MSDTC issue is your main concern :) Are you sure you checked the Network DTC access checkbox as described here: http://msdn.microsoft.com/en-us/library/dd897483(v=bts.10).aspx For more information on troubleshooting these specific issues, please ...


4

Based on your description, the title of your message is slightly inaccurate. Dehydration is not the problem, the missing message is. What you need to do is wrap the Receives in a Scope Shape with a Timeout set. Then, if the other Message does not arrive within the Timeout, a Timeout Exception will be raised, which you can handle and take the appropriate ...


1

Yes that's correct. You can open the settingsfileGenerator.xml in excel and can add as many variables as you want in left most column and their values in specific environment columns. Use ${variable_name} in master binding file, where variable_name is same as value you have entered in excel left most column. In your btdf proj file You should add following ...


0

In the expression shape add SucessMessage = new System.Xml.XmlDocument();


0

creating a memory stream and writing to it, which means copying the data Yes but after that the string can be abandoned. An UTF8 encoded buffer will consume only half as many bytes as the original string. Don't solve problems you don't have.


0

Are you using a default pipeline? Have you checked the tracking check boxes on them? There is some bug where the pipeline tracking is disabled for default pipelines. More info here: http://blog.ibiz-solutions.se/integration/biztalk-global-pipeline-tracking-disabled-unexpectedly/


-1

Stream can only copy data. In addition, it deals in bytes, not chars so you'll have to copy data via the decoding process. But, If you want to view a string as a stream of ASCII bytes, you could create a class that implements Stream to do it. For example: public class ReadOnlyStreamStringWrapper : Stream { private readonly string theString; ...


1

You can prevent having to maintain a copy of the whole thing, but you would be forced to use an encoding that results in the same number of bytes for each character. That way you could provide chunks of data via Encoding.GetBytes(str, strIndex, byteCount, byte[], byteIndex) as they're being requested straight into the read buffer. There will always be one ...


-2

Have you used singleton pattern orchestration for this ? If no then try it once and see if your getting same problem as I suspect it is facing race condition


2

You can have only one disassembler component in Disassemble stage, I mean you can have more components but only one of them can disassemble the message. It is based on IProbeMessage interface implementation. If you want to use your own Disassembler also want to use FF Disassembler, then you need to wrap FF Dissasembler from your own.


2

Assuming the Flat File Disassembler is not actually splitting the document, meaning it returns only one message, here's two options: Wrap the ffdasm component in a non-disassembler component and add it to the Decode Stage, then put you new Disassembler Stage friendly component in the Disassembler stage. Use a Loopback Adapter, such as my company's free one ...


0

A few things: You don't have to create the X12 transactions, BizTalk Server ships with schemas X12 and EDIFACT. You probably don't even need to customize them. In the beginning, you can probably rely on the Trading Partners to provide Companion Guides, especially if they have a more established EDI implementation. If they don't, and you need to create ...


1

No, you cannot add new artifacts to the System application. The best you can do is Deploy to a 'shared' Application, then Reference that from any other Application that needs to use that Pipeline.


0

AS2 is a standard for data transport security, EDI being an Electronic data interchange, so AS2 EDI means the standard for exchanging Electronic Documents securely. EDIFACT is standard for electronic documents which are tagged flat files with a nested looping structure which dates back to when electronic documents needed to be as small as possible due to ...


0

Yes, you can because the Registry entries include ones for the path. However, I strongly recommend against this. Adapters and Pipeline Components should be in the GAC. BizTalk Server itself uses the GAC for Adapters and Pipeline Components.


0

There is no way to suppress BizTalk projects warning. All you can do is to avoid them


0

I can see two issues here. First, you have configured GET on the receive port and you try a POST. If the request body are meant to be empty, you should probably use a GET. If you want to use POST change to POST in the configuration. Second, when BizTalk receive the request, the reqest body is inserted to the message body. If the message body is empty, ...


1

For clarity, to remove whitespace, the generally preferred approach is something like: public string removeWhitespace(string input) { return Regex.Replace(input, @"\s+", ""); }


1

Try using this code in the Map, public string removeSpace(string param1) { return param1.Replace(" ", ""); }


0

Not really an answer, more sharing of expierence; In my team we've had discussion on this issue. The argument for maps was that it is understood by most colleagues (as it is touched by every basic BizTalk training), and XSLT not. I've personally worked with XSLT for a long time, before i started working with BizTalk, and find the mapper tool very .. ...


0

We experienced the same situation and error with both BizTalk 2009 and BizTalk 2013, each set up with two App servers and one SQL DB server. When our VMware does the final step of the Snapshot backup on the Application servers, it freezes the application server for about 10 seconds, preventing it from receiving packets. On SQL Server 2008 and 2012, it by ...


0

Seems like the WCF-WebHttp adapter for some reason sets the UseDefaultWebProxy to false. It works as expected when I added an endpoint behavior that just sets that property to true. var binding = endpoint.Binding as WebHttpBinding; if (binding != null) { binding.UseDefaultWebProxy = true; }



Top 50 recent answers are included