Edit Note that the Block object does not have ConnectionBus or Removable properties. You will have to change the code to remove references to Drive object properties for the code to work. /Edit If you want to connect to Block, not Drive, then instead of drive_info = v.get('org.freedesktop.UDisks2.Drive', {}) try drive_info = ...


0

Another workaround is to just manually copy the dbus files/libraries directly to your virtualenv: cp -r /usr/lib/pythonX.X/{site or dist}-packages/dbus myvirtenv/usr/lib/pythonX.X/site-packages/ cp -r /usr/lib/pythonX.X/{site or dist}-packages/_dbus_*.so myvirtenv/usr/lib/pythonX.X/site-packages/


1

I finally found the issue. When Dbus looks for configuration files for punching out permissions (like ownerships) the file not only must be in system.d/ but it must also end in .conf. My configuration file "org.dbus.arduino" should have been "org.dbus.arduino.conf". I removed the code from system.conf. Confirmed I no longer had permissions, created a ...


1

It took me a while to figure this out. You can do this by using the functions: DBusMessageIter iter,subIter; //append arguments to the Set() method. (string interface, string property, value) dbus_message_iter_init_append(msg, &iter); dbus_message_iter_append_basic(&iter, DBUS_TYPE_STRING,&interfaceString); ...


0

This question has some good ideas in the answers including for passing large amounts of data by writing the data to a file and passing the filename, or using a named pipe. Writing to a file and passing the file name might be the easiest to implement.


0

Without using GLIB or any external library, the best way I've found is outlined in this post. It requires knowing the structure of the datatype ahead of time, which is a bit annoying. However, you can use dbus-monitor to see what DBUS is sending first. Then you have to make an iterator for each level of the array. See the DBUS message documentation for ...


0

I did not continue with BlueZ 4. I upgraded to BlueZ 5 and PulseAudio 5, which work better together than the previous versions. After, I was able to finally use the pactl loopback module. (See this post for more details.)


0

I can't just comment... you haven't imported process module, or its members (Popen, PIPE).


0

The answer was in the question I think. I believe that the reason that I couldn't call the method that I created was that I didn't have a leading slash in my path argument of the method call DBus message. As in: /com/example/whatever correct com/example/whatever incorrect The guide I referenced in the question has the minimum requirements to do it. I ...


1

Yes, you should be able to do this (with a bit of work) through QtDBus. Fundamentally, any client on a message bus can subscribe to any message -- limited only by the bus's security policy. (So there is no way to monitor an explicitly uncooperative application, unless you have debugging access to it or to the message bus.) The key is that you will want to ...


0

problem was with jackdbus server, i didn't start it properly. i have a firewire audio card. so now I use the following: alsa_control start ds firewire then it's able to properly connect to jack.


1

For the time being, the only DBUS interface that nautilus implements is this: http://www.freedesktop.org/wiki/Specifications/file-manager-interface/


0

As mentioned in /etc/dbus-1/system.conf <!-- Holes must be punched in service configuration files for name ownership and sending method calls --> <deny own="*"/> ... Add your own configuration file (e.g astcore.conf) in /etc/dbus-1/system.d/ to allow your app to own the specific bus name.


0

Thx, The DISPLAY=:0 did not quite resolved the problem. I did not recompiled dbus without X11, but I am using system bus and is OK. I have to use system bus because the lighttp server talks to a service via dbus.actualy I enabled rights in dbus config files and is just OK.


0

I assume there is no activity in that project. However, many people really like the idea of a hud for gnome! Is the script you posted here all the work that went into this or do you have some files left over which are better?


0

The Object returned by getValue() needs to be cast to the right type corresponding to the Dbus types. By digging a bit more into the DBusStructType and DBusStruct, the Object returned by Variant.getValue() is an Object[] in the case of a DBusStruct. Here is the working code: public void Set(String interface_name, String property_name, Variant new_value) ...


0

I have not used the Type Interface at all, but it looks like the only known implementing class is Class. I would suggest Casting it as a Class and then calling cast. public void Set(String interface_name, String property_name, Variant new_value) throws Exception { Type t = new_value.getType(); Object s = new_value.getValue(); ...


0

Thank you All for replay ... I found what I need import dbus session_bus = dbus.SessionBus() purple_obj = session_bus.get_object("im.pidgin.purple.PurpleService", "/im/pidgin/purple/PurpleObject") purple_int = dbus.Interface(purple_obj, "im.pidgin.purple.PurpleInterface") my_account_id = ...