One possible method would be to have another set of heartbeat messages from the main thread to the heartbeat thread. If it stops receiving messages for a certain amount of time, it stops sending them out as well. (And could try other recovery such as restarting the process.) To solve the issue of the main thread actually just being in a long sleep, have a ...


0

Your configuration will not work if server 2 goes down. Your replica set has 3 voting nodes, two of which are on server 2. If server 2 goes down, the set has 1/3 members up, and so cannot maintain or elect a primary. You need 2/3 able to talk to each other to elect a primary. Your description of the problem is not consistent with how replica sets behave - ...


0

Temporary queues are not clustered. When you do request/reply you need to add some logic that recreate the temp queue for InOut in case of a failover - this does not happen automatic.


0

After further investigation it seems to me that 2012 either defaults to or is hard-coded to "persistent mode" and they've disabled changing the value with the GUI.


1

I am not an expert on all of this, especially, I am not sure how C# handles the db connection. What I have seen on one of our applications was that you open a connection with the db in the AlwaysOn cluster and when you fail over the application the connection is still using the same underlying TCP connection that is actually going to the node which by now ...


1

Yes, the driver does throw a exception. Technically it is the right thing to do, especially if you wish to know when the set fails over. What you need to do is catch the exception and do a retry. Your biggest problem here is that for some reason you are evaling. Eval requires to be run ONLY on the master, as such when a set fails over it has to wait for a ...