34

First check with dmesg | grep tty if system recognize your adapter. Then try run minicom with sudo minicom -s, go to "Serial port setup" and change first line with /dev/ttyUSB0. Don't forget to save config as default with "Save setup as dfl". It works for me on Ubuntu 11.04 on VirtualBox.


31

If you are developing for Windows, the com0com project might be, what you are looking for. It provides pairs of virtual COM ports that are linked via a nullmodem connetion. You can then use your favorite terminal application or whatever you like to send data to one COM port and recieve from the other one. EDIT: As Thomas pointed out the project lacks of a ...


17

Not all modems support caller ID. And for those that do, the implementation varies between manufacturers. There caller ID is passed through the serial data so you will have to use the TAPI library (or Windows' HyperTerminal to test it). The caller ID number typically appears between the first and the second ring. You will need to issue a command to the ...


17

I know this is an old post, but in case someone else happens upon this question, one good option is Virtual Serial Port Emulator (VSPE) from Eterlogic It provides an API for creating kernel mode virtual comport devices, i.e. connectors, mappers, splitters etc. However, some of the advertised capabilities were really not capabilities at all. EDIT A much ...


13

I assume you are interested in a IA-32 (Intel Architecture, 32-bit) CPU and Microsoft Windows. The Model Specific Register (MSR) IA32_THERM_STATUS has 7 bits encoding the "Digital Readout (bits 22:16, RO) — Digital temperature reading in 1 degree Celsius relative to the TCC activation temperature." (see "14.5.5.2 Reading the Digital Sensor" in "Intel® 64 ...


12

Cache coherent systems do their utmost to hide such things from you. I think you will have to observe it indirectly, either by using performance counting registers to detect cache misses or by carefully measuring the time to read a memory location with a high resolution timer. This program works on my x86_64 box to demonstrate the effects of clflush. It ...


12

Without a specific kernel driver, it's difficult to query the temperature, other than through WMI. Here is a piece of C code that does it, based on WMI's MSAcpi_ThermalZoneTemperature class: HRESULT GetCpuTemperature(LPLONG pTemperature) { if (pTemperature == NULL) return E_INVALIDARG; *pTemperature = -1; HRESULT ci = ...


11

You can read it from the MSAcpi_ThermalZoneTemperature in WMI Using WMI from C++ is a bit involved, see MSDN explanantion and examples note: changed original unhelpful answer


11

I use com0com - With Signed Driver, on windows 7 x64 to emulate COM3 AND COM4 as a pair. Then i use COM Dataport Emulator to recieve from COM4. Then i open COM3 with the app im developping (c#) and send data to COM3. The data sent thru COM3 is received by COM4 and shown by 'COM Dataport Emulator' who can also send back a response (not automated). So with ...


10

You may be able to get a figure for the power consumption of your process, but it will only be correct in isolation. For example, if you ran two processes in parallel, you're unlikely to fit a straight line with good accuracy. This is hard enough to do on embedded platforms with a complete break-out of every voltage rail, let alone on a PC where your one ...


9

I have this thing called a coffee machine. It dispenses liquid energy and helps keep me going.


9

You might want to look into PHP Serial by Rémy Sanchez. There's an article about it here: Controlling the Serial Port with PHP Also have a look at this example provided by jared at dctkc dot com on the PHP site: http://php.net/manual/en/function.fopen.php#20935


8

The interface between the robot and the software must be defined first ; not necessarily exhaustively, this could be done incrementally. Start small, for instance with basic moves (forward, backward), then, once it has been fully tested, both in isolation and integrated, add some behaviour (e.g. turn left, turn right), retest. That way, the whole team can ...


8

I would recommend rethinking this design. First off, Stopwatch just does what it says - it acts like a stopwatch. If you want an event to fire at specific intervals, you'll want to look at the various Timer classes. That being said, I would recommend sharing your Timers across the gadgets. You will find that everything performs much better, and is ...


7

I am not sure if you are the author of the program or you're just trying to compile a program you got from someone, but looks like #include <asm/io.h> should be replaced with #include <sys/io.h>. See the results of this google search for more information.


7

A stopwatch is nothing but a variable holding the result of Windows API call QueryPerformanceCounter(), it has no overhead while it's "running". Stopping it calls QueryPerformanceCounter() once more, so performance should be okay. That said, I agree with Reed Copsey, you need to rethink your design. With such a large number of gadgets, I'd start thinking ...


7

This is the topic of ongoing research. So don't expect any definite answers. Some publications you might find interesting are for example: Chunling Hu, Daniel A. Jiménez and Ulrich Kremer, Efficient Program Power Behavior Characterization, Proceedings of the 2007 International Conference on High Performance Embedded Architectures & Compilers ...


7

I know this isn't what you want to hear, but there is no all-inclusive way to do what you want. Individual makes and models have their own way of exposing it. For example, I've done some work with Synaptic touchpads (fairly common) which expose a COM interface on Windows. That code won't work on any other touchpads. You could find a few common ones and ...


7

Rather than use the parallel port, have you considered using a serial device? Since you have a TTL signal, you'll possibly need a level converter to convert TTL to RS232 +/- 12V levels. Once you're using a serial device, you can use the standard serial ioctl() calls to detect a change in control signal status. Specifically, you could use the TIOCMIWAIT ...


6

It seems you have to either specify the DIGCF_ALLCLASSES flag to find all classes that match the given device instance id, or else specify the ClassGuid and use the DIGCF_DEFAULT flag. This worked for me: void error(DWORD err) { WCHAR buf[0x200]; FormatMessage(FORMAT_MESSAGE_FROM_SYSTEM, NULL, err, 0, buf, 0x200, NULL); wprintf(L"%x: %s\n", err, buf); ...


6

I think that's a no-brainer: WMI is the Microsoft-blessed way of providing performance and hardware information. That should be the way you provide the information you describe. There's plenty of precedent in the Win32_Computer and other hardware classes, which provide CPU details, memory size and so on (stuff that doesn't change with the software running). ...


6

There has been a small plastic duck on the top of my monitor since 1984. (The monitors get upgraded, the duck remains. It's actually a broken RSPB pencil sharpener, rather than the canonical rubber variety.)


6

Here is code snippet from this article Hope it helps //S.M.A.R.T. Temperature attritube const byte TEMPERATURE_ATTRIBUTE = 194; public List GetDriveTemp() { List retval = new List(); try { ManagementObjectSearcher searcher = new ManagementObjectSearcher("root\\WMI", "SELECT * FROM MSStorageDriver_ATAPISmartData"); ...


6

How processor deals with reset button hardware interrupt. The reset signal does not generate a hardware interrupt! A CPUs contain a special, so called reset circuit, which set the CPU into a well known, initial state. Among other things it sets the so called instruction, or program counter to the reset vector address. And Why there is need of reset ...


5

It is possible, but there are some things about it you should note: You still have to have caller ID supported by your carrier/provider. A basic POTS line won't include this information unless the carrier has done some extra work to add it. So you can't do this to avoid paying an extra caller ID fee. It's not built into .Net. You'll have to call into ...


5

An alternative is to use the event notification mechanism from FTDI, this way you don't need a blocking thread to read out data: public FTDISample() { private AutoResetEvent receivedDataEvent; private BackgroundWorker dataReceivedHandler; private FTDI ftdi; public FTDISample(string serialNumber){ ftdi = new FTDI(); ...


5

I have used mongoose to control a server through HTTP/HTML. I generated the pages directly in C++, but I don't see why you couldn't invoke the PHP interpreter to render page contents.


5

Unless you write a browser plugin (not very portable), a browser viewing a web page can't just call functions in your C++ program. If you're going to control a device from a browser, basically your C++ program needs to incorporate a web server. So, when a link or a button is clicked, the C++ program will receive a connection on a socket it's listening to, ...


5

you can check out all the gory details in the Intel specification. The gory details are in chapter 8.1. Here is an excerpt: Following power-up or an assertion of the RESET# pin, each processor on the system bus performs a hardware initialization of the processor (known as a hardware reset) and an optional built-in self-test (BIST). [snip] At ...


5

The VMware products would be suited best for this. You can add virtual serial and parallel ports and forward them to a physical port on the host, or even to a file or a named pipe. You can also connect any USB device that is connected to the host machine. This works with VMware Workstation, but might even work with the free VMware player too.



Only top voted, non community-wiki answers of a minimum length are eligible