New answers tagged

0

First of all, make sure that you did all the steps described in the Deploying an Office Solution by Using Windows Installer article. Do you see the add-in listed in the COM add-ins list in Outlook? Make sure the right windows registry hive is used. Note, it depends on the Outlook/Windows bitness.


0

OK I solved it. (kind of) There is a simple trick what you can do to trick the InstallShield to think it is already installed even if it is not. First you need to locate all the registry entries with your UpgradeCode and ProductCode (it should be 3 entries for the UC and 5 for the PC) normally created by the InstallShield. Also note that both GUIDS are ...


0

As you are saying, you have created new MSI installer for upgrade. So in this case the component ID of components in which your files are present, got change. So you need to set values of Component ID with the component IDs of your installer 1.0.1.45. Or you need to create different components with the same target path. Also you can validate your upgrade ...


0

A similar approach to @Peter Coppins answer. This, I think, is a bit easier and doesn't require the use of the Orca utility: Check the "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Office\14.0\Common\FilesPaths" registry key and make sure the value "mso.dll" is NOT present. If it is present, then Office 64-bit seems to be installed and you should not need this ...


-1

I followed these steps: Add a component and add the file to be registered to the component Set the file as the key file Extract the COM data for the key file Clear the key file Delete the file from the component Ensure the component's path gets set to the location where the file resides Temporarily register the component on the machine Export the ProgID ...


0

Fix was provided by Aschipfl. Placing a "" after START to create an empty string resolved the issue. Without the string following the START command, the batch was incorrectly processing my filepath and switches.


0

I do not think this can be done. The Inno Setup does not use the Windows Installer, so the InstallShield won't even know that your product is already installed. And Inno Setup uninstaller cannot know that the InstallShield installer is starting. The best what you can do is to have your Inno Setup installer remove the InstallShield installation and install ...


0

A stock InstallShield template automatically authors a prevent downgrade rule into the MSI. Assuming your InnoSetup project was created using the same UpgradeCode as the InstallShield project this should work automatically. If you gave your new InnoSetup project a new UpgradeCode GUID and authored a remove legacy product type rule using the old GUI in the ...


0

It seems that fiddling with the UI sequence can have disastrous consequences. We needed to prompt for some information during the upgrade, and I believe that by including one of our dialogs which had been designed to flow well in the setup and maintenance sequences in the "SetupResume" sequence too, which I believe is what is used on an upgrade, we caused ...


0

What do you mean by?: but my problem is that it fails unless I actually deploy something with the actual original "bundle" setup You don't want those MSI's included in the wrapper/suite/bundle package? Advanced Installer and Wix Toolset also have support for bundles. Here is a tutorial for Advanced Installer suite installations.


1

You need to add required Prerequisites during publish/setup of your application. App.config file--> change name and add same code in your connection code as shown below: Read More...


0

Copy your database in other Computer and change the connection string from app.config file.


0

Another late reply. For my situation, I merged multiple branches together, and something is lost along the way. It was probably a setting file or something with the gitignore file. Anyways, I got that same -1501 could not compress file error. The reason was the build order of projects in the solution. Incorrect build order caused VS to look for ...


-1

I had the same boring problem. It worked for me just moving the KinectAudio10.dll from the SysWOW64 to another folder. I guess that InstallShield when it does not find the ddl it just does nothing. I don't use any kinect's sound in my app so i don't have any side effects.


2

InstallShield does not have a .wxs importer. However hidden in the File > Open dialog, in the drop down part of the Open button, is the option to Open with Wizard (or, I believe, Open As > Wizard in earlier versions). You can use this to convert a built .msi file into a project file. However if you want it to be a good project file, you will likely still ...


0

The log is not of an install. e.g. it says "Skipping RemoveExistingProducts action: current configuration is maintenance mode or an uninstall" and "Component: PublishRS.exe; Installed: Local; Request: Null; Action: Null" means that the component is already installed, the operation is maintenance "do nothing" so the action is null. The MSI is not doing an ...


0

I had the same problem recently (with Installshield 2015). The problem was, that under Application Data/Files and Folders there was a definition for a folder called .. - so the setup would try to create a folder .. on the target system, which of course doesn't work. Deleting that folder definition and moving its contained files to the parent folder ...


2

Installshield basically just moves over all of the files to the target machine's folder. Lets say you are going from version 1.0 to 3.0. Is there any real point in your case to upgrade to 2.0 before going to 3.0? Or could you really just lay down 3.0 directly? Unless you NEED an updater, then there's no point in having one. How we handle it, is that we ...


0

I ended up with 2 CA's one for 32 bit and one for 64 bit. The 64-bit: "[SystemFolder]cmd.exe" /C "echo y | reg delete HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Microsoft\Windows\CurrentVersion\Uninstall\InstallShield_[ISACTIONPROP1]" As a commit execution CA with execute condition: VersionNT64 AND IS_MAJOR_UPGRADE Where "ISACTIONPROP1" is defined in an ...


0

I'm wondering if the odd try / catch / rethrow is causing the problem. Normally, using NUnit, one doesn't catch the exceptions one is asserting on. A simpler way to write the test would be... var ex = Assert.Throws<SoapException>(() => { // Code that throws SoapException } Assert.That(ex.Message.StartsWith(...)); BTW, I couldn't decide ...


0

I was able to resolve this issue, so it is possible. The setting I mentioned above are the correct settings needed to allow the service to update. This was just a case of human error that was causing my problems.


0

There are multiple pieces to this question, so I'm going to answer them at a high level. That should help you figure out what you want more detail on so you can ask it in a new question. It's possible to associate Suite/Advanced UI features with MSI features, but I don't really recommend it. There are a lot of caveats to the approach in that blog post. We'...


1

I would suggest not trying to interleave Basic MSI table-driven dialogs and InstallScript code-driven dialogs. It's going to be difficult, and likely will result in some odd parenting issues at best, or loss of focus at worst. The goto <previous dialog label>; approach works as part of a script that shows several dialogs. By jumping backwards, it then ...


1

As it turned out, this is a deferred custom action, hence the INSTALLDIR variable is not initialized (nor any other Windows Installer built-in variables). Change it to an Immediate-type custom action (and relocate it to an appropriate location in the execution sequence) and it should work.


0

To fix the shortcut's parameters, start by ensuring they are correct. Debug your function to verify you are actually passing what you want to. As commented, INSTALLDIR may not be available directly to an InstallScript custom action. A simple way to "debug" would be to add calls like MessageBox(szCommandLine, 0); to key points in your code. If you find you ...


1

This doesn't look complete; how do things get from /vSERVERTYPE=Server to serverInstallSwitch? From the command line format, I'm expecting this is an MSI-based install, hopefully a Basic MSI with custom actions. Thus I would expect to see a call to MsiGetProperty(... "SERVERTYPE" ...), and use of Feature Conditions to hide the feature. (Note that this ...


0

copy guid from /General info/"product code" to /Upgrade PAth / Upgrade code copy guid from /General info/"product code" to /General info / Upgrade code pres button "..." in /General info/product code to generate new guid Optional settings. In /Upgrade PAth / Upgrade code disable max version enable min version, for example you can put version 0.0.0.1 for ...


0

I found the answer on this Stackoverflow question (custom action must be set as Deferred Execution , Absent from Sequence of Install UI Sequence , After InstallFiles of Install Exec Sequence with condition PATCH. http://stackoverflow.com/questions/8167663/installshield-with-custom-action



Top 50 recent answers are included