Tag Info

Hot answers tagged

5

AFAIK, SCNAPI32.dll is a native dll, which is present on motorola devices (loaded from ROM) and called by the Symbol dll's. The emulator is not a motorola device so it does not have these libraries installed. If the device has an USB cable you could hook it up using ActiveSync (or windows mobility center) and debug on the device itself; I don't know if ...


5

The 'missing' FNC1s are not present by design. The spec (GS1 General specifications) states that FNC1s in the first position shall not be represented in the transmitted message. Also, FNC1s are not required after fixed-length Application Identifiers, and after the last AI in a barcode. Your AI's 01 and 17 are defined with datalength 14 and 6. AI 30 is ...


3

I will post a dllImport example as continue of comments of @HemendraSharma. The above code is written for mobile devices and is used to change system hour. using System; using System.Runtime.InteropServices; namespace changeHour { public class cDateTime { [StructLayout(LayoutKind.Sequential)] private struct SystemTime { ...


3

I gave up on using the built in com port connection and opened a SerialPort object on the connection. SerialPort sp = new SerialPort(); sp.PortName = "COM" + connectedDevice.LocalComPort.ToString(); sp.BaudRate = 9600; sp.DataBits = 8; sp.Parity = Parity.None; sp.StopBits = StopBits.One; sp.Open(); sp.Open(); sp.DataReceived += new ...


3

There is no need to wrap anything you can use the scanner by Javascript. They provide some samples using scanner with Javascript for the use of Pocket Browser, you can combine the provided Javascript with asp.net to start the scanner and __doPostBack to the server. Download samples and pocket browser from: ...


3

It looks like you are trying to read a GS1-128. The first AI in your barcode (00) is the SSCC (AI reference here), which is a fixed length of 18 digits. So you'll know that AI 15 will start right after that. Regarding using DataWedge vs EMDK to read the barcode: DataWedge could not deal with the control characters in a GS1-128 when I tried it. Granted, ...


2

I ran into a similar problem with Symbol & Symbol.Audio. My error message was Can't find PInvoke DLL 'AudioAPI32.dll' It turns out there are simulated modes for some Symbol "devices". Motorola Symbol libraries detect those modes using registry of the device or emulator. To access the Emulator registry, you can use Visual Studio Remote Tools \ ...


2

Fisrt FNC1 is not supossed to be decoded as ascii102, but "]C1". Take a look at AIM Symbology Identifiers. Next FNC1s are supossed to be decoded as <GS> but it's probable you can't see them. Try to scan them in a text editor, save it and load it in a text editor like Scite where you can see control characters. You can configure Motorola's DataWedge ...


2

I've went thru this recently also, as I observed, it probably due to the scanner device is occupied by other application, where the scan request has been queued already, you can go to memory management, and kill the suspect app, and try your app again. Refer to the Symbol FAQ


2

You're after the lineGetGeneralInfo TAPI call. You want to look at the subscriber number, which is located using the dwSubscriberNumberSize and dwSubscriberNumberOffset members of the LINEGENERALINFO structure the call returns.


2

Something like this MSDN article? Or this one? (a favorite of mine). Or maybe an example of it in use for printing? Or maybe a card reader example? Or posibly Bluetooth via VB? The web has loads of examples. Generally speaking any example (desktop or device) that uses the SerialPort class will be completely applicable.


2

From Symbol's web site.


2

The docos state: Keyboard Supported feature - Only the following two API’s are supported on MC65. Symbol.Keyboard.KeyPad.SetKeyState. Symbol.Keyboard.KeyPad.GetKeyStateEx. Following keys are not supported in MC65. KEYSTATE_ALT, KEYSTATE_CTRL, KEYSTATE_NUMLOCK, KEYSTATE_NUMERIC_LOCK, KEYSTATE_CAPSLOCK For the MC65, Microsoft APIs ...


1

The DataWedge application did need to be disabled, (this can be done programmatically via the datawedge API from Motorola, Thanks Abdel for the hint here!). https://docs.symbol.com/ReleaseNotes/Release%20Notes%20-%20DataWedge_3.3.htm A little background on our Windows Mobile application for reference, we have a hardware singleton that contains interfaces ...


1

The first one is wrong as you are not connecting to port 0. Use the second one. I suggest trying 127.0.0.1 instead of localhost. You should also double check that the port that the RFID component is listening on is indeed 5084. You are currently specifiying too shot of a timeout. Try 10000 milliseconds, not 10. Finally, the RFID component needs to be ...


1

You can find a sample application when installing the Windows Mobile 6.5.3 Standard DTK (Developer Tool Kit) You can find this example in: C:\Program Files\Windows Mobile 6.5.3 DTK\Samples\PocketPC\CS\GPS C# Program description: Demonstrates how to use managed code to write a C# Windows Mobile Global Positioning System (GPS) application. This code ...


1

I usually use this snippet, below you will see for both CE and WM (commented). You just need to call the ExitWindowsEx(2,0) for CE, and SetSystemPowerState(NULL; POWER_STATE_RESET, 0) for Windows Mobile. The following sample delays the reboot 48hrs. // REBOOT.cpp : Defines the entry point for the console application. // #include "stdafx.h" #include ...


1

You can create your own window (Form) that displays the error message, but does not react on the enter key. It should contain a button which the user can click (as you wrote), however you need to make sure the button does not have focus when the window is displayed. (Because if it had focus, pressing the return key will "click" the button.) A simple way ...


1

Please check the AutoScale Settings and the FormFactor of your project: http://www.hjgode.de/wp/2013/04/19/windows-mobile-6-5-changed-screen-geometry/ I assume you have set QVGA in the project and AutoScaleMode=DPI and run the project on a VGA device. You can also change the picturebx to strech the image into the picture box size. So the image will be ...


1

A quick look at the ET1 Enterprise Tablet Integrator Guide suggests you just need to: Ensure that an application is open on the ET1 and a text field is in focus (text cursor in text field). Aim the Scan Module exit window at a bar code. Press and hold either Scan/Action button. The red laser aiming pattern turns on to assist in aiming. Ensure that the bar ...


1

Be sure to call Barcode2.Config.Scanner.Set(); After you set the variables. It is possible you need to set DecodeBeepTime to 0 also.


1

The first step is placing your application in a persistent memory location, like the /Application partition on the Motorola FX7400. Then you need to create a shortcut to your application and place it on the same partition. The last step is to create a .cpy file and place it in the /Platform partition (I can't remember the exact path, but it shouldn't be hard ...


1

I'm not familiar with the symbol library, but from what i can see the problem is the ReadNotify event being raised at some point after the "deinitialization" of the scanner. What you should do in the MainForm.CloseScanner() void is to first remove ALL handles added in the MainForm.InitScanner() and then call Scanner.DeinitSymbolReader(). Edit: You should ...


1

If you're gonna to use .net then you have to get Visual Studio 2008 and download the Windows Mobile SDK. They removed the support for creating Windows Mobile applications in VS 2010 and up. In Visual Studio 2008 you will find smart device project etc.. And there is also a Emulator for it. There is other options to create applications for these devices. ...


1

Like charlesbridge said, the displayed information does not completely match the data encoded in the GS1 barcode. The data inside the brackets is called an application identifier (AI). Each AI is followed by its data. For instance, (11)131011 means that the item was produced at October 11, 2013. If you want to recreate the displayed string, your ...


1

There is no way to guaranty that any of these fields are unique. All of them can be updated by printer or reader. So you should trust to your RFID tags supplier or print them by your own. EPC collision is not a problem for reader, only for your software.


1

I believe that the MC75A does not have UHF RFID, but only HF RFID which does not work with the samples and .dll provided with the EMDK. I have worked on the MC75A a year ago and you had to download a different package for that. Please let me know if this is not the case with your device. You might solve this problem in two ways: Downloading what Motorola ...


1

If you put the scanner in the stand and start your app the api will not toggle the presentation mode on. Either start the app and then place in the stand or lift the scanner tail an inch and drop it back to toggle it. There is magnet in the stand that triggers it. We are working with Moto to see if it can be handled better...


1

The answer is you don't or can't...you instead use the Microsoft Bluetooth. Download this for windows mobile bluetooth on a motorola device...may work on other devices too. You can get from the mobile samples, I found it here on my hard drive...C:\Program Files (x86)\Windows Mobile 6 SDK\Samples\Common\CS\Bluetooth. I added this to my project then all I ...