New answers tagged

3

Based on the error message below I know you are using EMU8086 as your development environment. INT 21h, AH=09h - address: 170B5 byte 24h not found after 2000 bytes. ; correct example of INT 21h/9h: mov dx, offset msg mov ah, 9 int 21h ret msg db "Hello$" I'm no expert on EMU8086 by any stretch of the imagination. I do know why your ...


-1

I found a solution.. I don't know why it's depending on it but.. here it is: data segment choice db ? snum1 db 4 dup(?) snum2 db 4 dup(?) num1 db ? num2 db ? res db ? sres db 4 dup(?) msg1 db "Enter first number$" msg2 db "Enter second number$" msg3 db "Press any key to procced$" msg4 db "The result is $" ...


0

I reviewed your code and concentrated on the following sequence of instructions: mov bx, offset choice ; here you set BX to the address of 'choice' mov ah, 1 int 21h ; here you 'READ CHARACTER FROM STANDARD INPUT, WITH ECHO' mov [bx], al ; because INT 21h does preserve BX, you are writing back the result of the ...


2

Found the error in your code : the file is been opened in READ ONLY mode, so you can't write it : proc OpenFile ;Open file mov ah,3Dh mov al,2 ;<================== 0:READ ONLY, 1:WRITE ONLY, 2:READ/WRITE. lea dx,[filenameStr+2] int 21h jc openerror mov [filehandle],ax ret openerror: mov dx,offset ErrorOpenMsg mov ...


2

You tagged your question with the stack tag. If you hover your mouse over this, you'll receive the information, that a stack is a LIFO(last-in-first-out) data structure. The problem with your code is, that you PUSH one value in and (possibly) POP several values out which messes up the stack. See, in TRIANGLE: you push one value to the stack: PUSH AX CALL ...


1

\r\n Odd to say I remember it because it is the opposite of the typewriter I used. Well if it was normal I had no need to remember it... :-) *Image from Wikipedia In the typewriter when you finish to digit the line you use the carriage return lever, that before makes roll the drum, the newline, and after allow you to manually operate the carriage ...


0

The system you're using doesn't have sprites or other independent object moving above the background, so you have to redraw the whole scene every frame.


0

Your problem is that the install script was written for the MS-DOS command interpreter (COMMAND.COM) and isn't compatible with the Windows XP command interpreter (cmd.exe). The specific problem is that the XP interpreter gives special meaning to double quote characters (") while the MS-DOS interpreter doesn't. This causes the following line to be interpreted ...


1

You are reading ascii characters and not converting them in numbers. I don't see the part where you try to write the result (beware, this works only if there is no carry! 9+2 -> ascii ';') mov dx, offset message1 int 21h mov ah, 01h int 21h mov bl,al ; save what you read sub bl,48 ; subtract '0' ... add bl,al ; won't ...


1

In your CODE SEGMENT, you are missing a coma to separate the segment declarations with ASSUME (at line 10). Change it to: ASSUME DS:DATA, CS:CODE


3

Been a while, but I think you can achieve what you are trying to do by placing the code segment first. Then place all the initialized data at the start of the data segment followed by all the uninitialized data in the data segment followed by the stack segment which is all uninitialized. Since all the uninitialized data has been forced to the end, it won't ...


3

No, you cannot do that. If you want to run your app with SDL forget about DOS: DOS is not on the list of supported platforms.


1

When you call the function 0Ah in int 21h you give it a buffer in a certain format. The first byte (M1 here) says how many bytes the buffer has, the second will have the number of bytes read (L1 here) and after that the bytes that will have the actual characters read (P11 here). So after calling the read function L1 is initialized with the number of ...


0

do followings to write your custom interrupt handler SettingIntVector: mov ah,25h ;Here set your ah register for calling Interrupt vector mov al,22h ;Your Interrupt Address mov dx,IntHandlerCode ;Interrupt Handler int 21h ;Dos Interrupt IntHandlerCode: mov ah,9 mov dx, offset our_text mov ...


2

Your program has a few problems: Since the BIOS call used CX as one of its parameters, you effectively have destroyed your loop-control variable! push/pop it: mov cx,100 secnd: PUSH CX ... POP CX loop secnd ret You're treating the a variable as tenths and the b variable as units, but you only change the former one with a single inc a. You could ...



Top 50 recent answers are included