Tag Info

New answers tagged

0

Unfortunately no, there is no cleaner solution. If no objects from the NLog.Extended assembly are referenced (directly or indirectly) from your code, it will not copy it. This is of course a problem since the layouts are just strings and not a direct reference. You could use a post-build event, but that's an uglier solution in my opinion.


0

Actually, you can instantiate a console in parallel of a non-console program by using this code : static public class LogConsole { static public void Instantiate() { AllocConsole(); } [DllImport("kernel32.dll", SetLastError = true)] [return: MarshalAs(UnmanagedType.Bool)] static private extern bool AllocConsole(); }


1

Take a look at Archival Options and Size-based file archival in the NLog documentation for the File target. You can use the maxArchiveFiles and archiveAboveSize parameters to keep the size of your log files within limits. <target name="file" xsi:type="File" ... archiveAboveSize="10240" maxArchiveFiles="10" ...


0

I'm an idiot sometimes. You can just stick them in the layout string <target name="logentries" type="Logentries" debug="true" httpPut="false" ssl="false" layout="${date:format=ddd MMM dd} ${time:format=HH:mm:ss} ${date:format=zzz yyyy} : ${LEVEL}, ${message}, ${SomeParam}"></target>


1

I've found ${exception:format=tostring} to be the best format for logging full details. NLog - How to Log Exceptions


0

You may want to take a look at the LogReceiverService target. It sends log messages to a NLog Receiver Service (using WCF or Web Services).


1

I don't know if I'd call it best practice but in my experience logging locally to files doesn't scale very well to a production environment: If you are load balanced across multiple web servers then you have to try and pull together log files from multiple sources and correlate events you have to log in to production boxes to try and retrieve your logs in ...


1

You can add an Assembly binding to your web.config <runtime> <assemblyIdentity name="MongoDB.Driver" publicKeyToken="f686731cfb9cc103" culture="neutral" /> <bindingRedirect oldVersion="0.0.0.0-1.10.0.62" newVersion="1.10.0.62" /> </dependentAssembly> <dependentAssembly> ...


1

The MemoryTarget.Logs property implements IList. Why not just clear it like this: MemoryTarget.Logs.Clear();


1

I found the answer, so I use ${processid} on NLog config file it will create different proccess id per application. Thank you


0

I enabled nlog exception and found the problem. The issue was the blank bcc and cc. I removed them and the emailing worked fine.


0

/** * class used to optimize loggers * * Logger.Trace("info "+bigData.ToString()); * Logger.Trace("info {0}",bigData.ToString()); * both creates and parses bigData even if Trace is disabled * * Logger.Trace("info {0}", LazyJsonizer.Create(bigData)); * Logger.Trace(LazyJsonizer.Instance, "info {0}", bigData); * creates string only if Trace is ...


1

Looks like you're missing a "layout=${defaultLayout}" attribute in your File target. <target xsi:type="File" name="rollingLocalFile" fileName="${localLogDirectory}\${machinename}-log.txt" archiveFileName="${localLogDirectory}\${machinename}-log.{##}.txt" archiveAboveSize="1048576" maxArchiveFiles="10" ...



Top 50 recent answers are included