Tag Info

New answers tagged

1

Calling cl /? will give you a list of options. /LD is the flag to create a dll cl's options are also documented online https://msdn.microsoft.com/en-us/library/fwkeyyhe.aspx However, I'd recommend moving away from creating these files yourself, and towards a more general, more powerful solution, like cmake or you might find your scripts become quickly ...


0

If you have a button that you're using for submit, you can easily set it as the default by using the IsDefault=true (wrote a tip about doing this and the cancel for the escape here.) Other than that, you'll have to have somewhere to write it (yet you don't want a textbox? you can select it by default, or tab into it if you don't have the focus there), and ...


0

serialPort1.Read(rs, 0, 22); You cannot ignore the return value of Read(), it will not be 22. Nor can you ignore e.EventType if you invoke right away. Which you shouldn't, collect the entire response before you do. You just need another variable to keep track of how many bytes you've received. Fix: byte[] rs = new byte[22]; int rsCnt = ...


0

sounds like you want to use Column Layout. set the Detail.ColumnCount property to 2 then set the direction to either horizontal then vertical or vertical then horizontal. http://arhelp.grapecity.com/webhelp/AR9/index.html#GrapeCity.ActiveReports.v9~GrapeCity.ActiveReports.SectionReportModel.Detail~ColumnCount.html hope this helps.


0

Sum of more than One Columns Quantity of More than one dataset in rdlc.=Sum(Fields!QUANTITY.Value, "Tone") +Sum(Fields!QUANTITY.Value, "Buffalo") +Sum(Fields!QUANTITY.Value, "Cow")


2

You should not attempt to detect memory leaks prior to releasing all memory. Calling _CrtDumpMemoryLeaks(); prior to free-ing everything that you have allocated is bound to detect false "leaks" that are simply memory in active use by your program. Moving the check to the end will fix the problem: S=(char*)malloc(3); ...


0

This is an MVC issue. Same problem was seen here: ASP.NET MVC VS2010 Crystal Reports Beta 2 Can't Print, Export, Zoom, or Change Pages I wound up using an iframe in my view with the webform which had the CRV in it as the source. Worked like a charm.


0

To connect to a ssms2014 database from visual studio 2013, in the new connection wizard I had to change 'data source' from 'ms sql server database file' to '.net framework data provider for sql server..'. Then I was able to enter [computer name][username] for windows authentication.


2

This is a red herring. I unpinned the application from the task bar, and re-pinned it. They now both have the same name... it has just been sitting there since the change in name was made in the AssemblyInfo.


4

will any memory bound application benefit from high memory throughput of tesla(cc2.0) more than high number of cuda cores of geforce (cc5.0)? A memory bound CUDA application will likely run fastest on whichever GPU has higher memory bandwidth. There are certainly other factors that could affect this, but this is a reasonable general principle. I'm not ...


0

Instead of a_Myana(0).Detail(0) = New DT_AnalyseDetail a_Myana(0).Detail(0) = a_Mydet(0) I set a_Myana(0).Detail() = a_Mydet and it works :)


0

2) ran setup That's where you went wrong. Three ways you can tell, "vcvars32" is a hint that this sets up a 32-bit build environment. And the linker error tells you that you are linking the 32-bit version of LIBCMT. Typing "SET LIB" at the command prompt shows you that LIB has the wrong value, pointing to vc/lib instead of vc/lib/amd64. Do favor the ...


0

I see the other answers are quite old. In 2015 you can do it like this: click on the VisualSVN menu item and then on "Set Working Copy Root..." Then you can browse to the solution folder on disk.


0

Maintain two .sln and .csproj to make it work in both version. According to http://stackoverflow.com/a/1027283/713789 there is no way to prevent Visual studio to do this.


-1

//Client var c = Protocol.Chat; stream.WriteByte((byte)c); //Server var header = (Protocol)stream.ReadByte(); switch (header) { case Protocol.Chat: //Handle Chat break; case Protocol.Login: //Handle Login break; case Protocol.Disconnect: //Handle Disconnect break; }


0

Assuming CopyFromScreen is not a custom free function that isn't included in your example, it is member of the Graphics class. You should invoke it as such (as you do with Graphics::FromImage() in the line above: graph = Graphics::CopyFromScreen(bounds->X, bounds->Y, 0, 0, bounds-> Size, CopyPixelOperation::SourceCopy); EDIT To address your ...


0

How to solve the above warning? Because Val_MAX is compile time constant, you can use it in pre-processor to filter out the if statment. #define Val_MAX 0 int main() { #if Val_MAX != 0 printf("The value is %d",Val_MAX); #endif return 0; } To get rid of the warning. Another less preferred way used by some programmers is to fool the compiler by ...


0

Your preprocessor directive will replace VAL_MAX with 0 it becomes if(0) So anyways it will be false always and your printf won't execute and so if condition is of no use


1

In your code, Val_MAX being a #defined value to 0 if(Val_MAX) is actually (you can check after preprocessing with gcc -E) if(0) which is not of any worth. The Following printf() will never execute. FWIW, a selection statement like if needs an expression, for which the value evaluation will be expectedly be done at runtime. For a fixed value, a ...


0

Try resetting Visual Studio Devenv /ResetSettings SettingsFile If it doesn't work you should consider reinstalling Visual Studio


0

Try Repairing Visual Studio. You can do this through Visual Studio Installer or by going at Control Panel/Programs And Features, selecting Visual Studio and then pressing Change.


0

In my case I received this error while using Excel Interop after enabling native debugging. Then in the debug mode I tried this: ?xlworkbook.sheets(1).name The process hung, I did not receive any answer, and after that every other thing, e.g. ?2+2 gave me that error: The expression cannot be evaluated while in run mode In order to again be able to ...


0

I had the same problem after updating of .NET: I uninstalled the .NET framework first, downloaded visual studio from visualstudio.com and selected "repair". NET framework were installed automatically with visual studio -> and now it works fine!


0

I think that this .dll file is related to the Microsoft Visual C++ 2010 Redistributable Package. Try removing the Microsoft Visual C++ 2010 Redistributable Package by using the Add or Remove Programs item in Control Panel. Then, install the latest version Visual C++ for your architecture (eg x64) from the site: ...


0

I agree that you need to better explain what you're trying to accomplish. If you hardcode num1 then perform a while num1 is equal to its initial value without ever modifying it, you're going to have an indefinite loop. In your example, it will just keep overwriting lbl1 to display the first item in your array. By "add one to the element every loop", do you ...


0

Not sure what you are trying to accomplish but the following is a stab at a solution private static void foo(string[] array1) { if (array1 != null && array1.Length > 0) { for (int num1 = 0; num1 < array1.Length; num1++) { string doSomethingWithArrayElement = array1[num1]; } } }


0

It is really not clear what You want to achieve, but maybe this will get You nearer to the goal: int[] array1 = new [] {0}; int num1 = 1; do { lbl1.Text = (array1[0]++).ToString(); num1++; } while (num1 < 9); or int[] array1 = new [] {0}; for (int i = 0; i < 9; i++) { lbl1.Text = (array1[0]++).ToString(); }


0

I was able to fix this problem by creating a 64 bit System DSN with the same name as the 32 bit one. Task Manager's Platform column shows that my Visual Studio (devenv.exe) is 32 bit and that my SQL Server Agent service (SQLAGENT.EXE) is 64 bit. That explains it.


0

Single stepping through a single thread seems to be mostly fixed in VS 2012 (with some caveats you can see in my link below). Breakpoints are a pain. Freezing and thawing threads is the usual workaround, as previous answers have stated, but it's tedious, and it can cause hangs when your thread waits on another thread that's frozen. These can be tough to ...


2

This line does not do everything you think it does: Dim a_Mydet(1) As DT_AnalyseDetail You believe it creates an array of DT_AnalyseDetail objects, but this does not happen. Instead, it creates an array of DT_AnalyseDetail object references. At this point, each of those references has a value of Nothing (the references don't refer to any object). These ...


0

Restarting Computer Emulator as well as Storage Emulator Worked for me :) .


0

You may also run into this problem if your control/service is inheriting from a generic class. The designer doesn't get along well with abstract classes in the hierarchy, since it has to instantiate them.


0

Editing .sln and .csproj is not always that easy or desirable. Once you get the error list you can see what projects have missing packages (also, the References node usually indicate that there are missing assemblies unless packages are source code, resources, images, or just text-based ones). Removing and then adding the packages is not a good idea unless ...


0

According to: MSDN: The file 'file' could not be added to the project, one of the reasons is relative paths being ambiguous. Meaning you have the file path Lib/MyApp/Files/abc.bmp both as a file path in your project folder as well as on your D: drive leading to ambiguity. That is my guess. Adding files by hand to the project folder can lead to issues.


0

I had the same issue when I was trying to copy over a project that was not in source control. The solution to the problem was that the bin directory was marked as read only (must have happened during the copy) and as a result the project was running on libraries built on a different host and it was unable to step through. Make sure you manually delete all ...


0

The problem was incomplete directories for the files I was loading. I neglected to check for a successful open or use try/catch. It was running fine in the IDE because the file directory was in a subdirectory of the working directory. When I tried to run it from the command prompt, the relative directory was no longer valid. I changed the filenames to their ...


0

If you can change the build process command lines, you might be able to integrate this into VS command line via /D parameter. See also this question for discussion on how output from some command can be integrated into another command.


0

A better option that I uses for the same problem is to create a new textbox class textboxClass and paste following code in its keypress event Private Sub commonTextbox_KeyPress(ByVal sender As Object, ByVal e As System.Windows.Forms.KeyPressEventArgs) Handles Me.KeyPress If Char.IsControl(e.KeyChar) Then If ...


0

The Way I got around this was the basically the same as Stag, but in 2010 the reset all settings can be found under Help> Import & Export settings> Reset All Settings


0

This is a known compatibility issue between vs2013 and opencv Try to replace vector<vector<Point> > contours; with vector<cv::Mat> coutours; That works in my case.


0

Another safe replacement of snprintf() and vsnprintf() is provided by ffmpeg. You can checkout the source here (suggested).


0

Below is the process that need to be done. Please see the link for more details. Resolution Find the Product.xml file in the bootstrapper folder: C:\Program Files (x86)\Microsoft SDKs\Windows\v7.0A\Bootstrapper\Packages\Crystal Reports for .NET Framework 4.0 Comment out the below BypassIf entry to install the 32bit version CRRuntime redist on the target ...


0

I tried your code. This example (probably) doesn't make sense, but your code works. This entire thing about VC10, VC12, ... can be quite messy. My suggestion is to try to follow the OpenCV HOWTO for Windows and Visual Studio. Maybe that way you will get around the problems you described in your question (or even find out what's wrong).


0

This is the same issue as described here NPM native builds with only Visual Studio 2013 installed If you have a version of VS2013 installed set this environment variable before running the npm command: set GYP_MSVS_VERSION=2013 or for VS2012 set GYP_MSVS_VERSION=2012 background reading: https://github.com/Automattic/socket.io/issues/1151


0

I've got around this issue by 'touching' the project file and therefore triggering Visual Studio to prompt the user to reload the modified project after the package manager has closed. So my Install.ps1 file looks like this: param($installPath, $toolsPath, $package, $project) # if there isn't a project file, there is nothing to do if (!$project) { return } ...


0

your project have an higher Framework that Visual studio can support.


0

I am also doing similar things, so I would like to share some views on it. I created a project in QtCreator, with a project file .pro, .h, .cpp, .ui files. The qt project file .pro is for qmake. Then I transferred my project to MSVC. All I do is to transfer the .h .cpp .ui files to a new directory, and add a CMakeList.txt there. If you have a existing ...


0

BaudRate is set in bits per second, so make sure this is high enough for what you expected transfer speed to be, so 8192 baud will be 1KB (1024 bytes) per second. Here is an article that might help you: http://www.codeproject.com/Articles/75770/Basic-serial-port-listening-application


0

VS2013 Update 4 I thought I had this problem but it was easily fixed by docking the Find Results window using the very bottom of the window position selectors. The files open in the same position as the Find Results when the window is docked in the positions immediately next to the centre position.


0

its easy just had to get the especific node and then get the value after calling the method who obtains the node in a XML format like <idAsign>12345</idAsign> as follows public XElement GetValuePartnerByID(string rutaPart, string id, string node) { XDocument archivoXML = XDocument.Load(rutaPart); XElement valuePart = (from ...



Top 50 recent answers are included