1

It's pretty easy to confirm WiX behavior just by logging the install. Consider the following code: <Component Id="test" Guid="{EAF11690-2396-4EBE-A74D-37FA1751BBC3}" MultiInstance="yes"> <File Id="test" Source="C:\windows\notepad.exe" KeyPath="yes" /> </Component> <InstanceTransforms ...


0

The article intends that you define or replace $(SourceCodeControlRoot) such that $(SourceCodeControlRoot) is the folder TFS exports to during the build. In your case, I'm guessing "C:\Builds\8\AppName\DailyBuild\". Of course, you probably don't want to hardcode it. You could pass a property setting to msbuild: ...


1

PublishProduct exists in the execute sequence not the UI sequence. The name of your custom action implies it should be scheduled before StartServices (also in the execute sequence) not the PublishProduct action. File costing is another important concept for you to learn but not really relevant here. I'd start with this required reading: InstallSite: ...


0

Honestly, because MSI is an open book ( Edit with ORCA ), it's best to do this type of enforcement (DRM) in the application at runtime. I could suggest all sorts of techniques in the MSI but they could be removed by someone knowing what they are doing. What is your "leaking" concern? Do you not trust your developers? Do you not trust your CM / Release ...


1

Ah, my Custom Actions elements were in the main Product.wxs file but in a different fragment, and that fragment wasn't getting referred to anywhere. I put in a ComponentGroup under that Fragment and made a reference to its ID under the Feature element - and it worked. My apologies.


0

You should add your CustomAction code so it's more obvious what you're trying to achieve, but, given your current code, the following would update your viewModel: [CustomAction] public static ActionResult MyCustomAction(Session session) { Record record = new Record(0); record.SetString(0, "My Custom Message"); ...


0

Yes this should be possible, if you use the Condition element under a Feature element, you can control the feature install level from a condition. <Feature Id="MyDependentFeature"> <Condition Level="1">(NOT INSTALLED AND &MyMasterFeature=3) OR (INSTALLED AND !MyMasterFeature=3)</Condition> </Feature> ...


0

Because I could not find a direct way to archive my goal I created an Custom Action and a (Pre-Build-)C#-Program. Before building the Installer I search for hidden files and folders and create lists for them with a C#-Program. After the files have been installed a custom actions marks these files and folders as hidden.


0

Expanding on Yan's answer, there's a very simple syntax if you use the Sql extension - You need both the MDF and LDF (Data + Log files) included for your SQL database, but then attach them by referencing the same filename. The following assumes a sql express server will be installed locally under the localhost\sqlexpress instance <Property ...


1

The simplest way to handle this problem is to design your application so that user modified data is in it's own files. This way the installer can then own the files it lays down and the application can merge the two sets of data at runtime. MSI won't delete or overwrite what it doesn't know about. Otherwise you get into complicated discussions of how to ...


1

You can set the hidden attribute for a file when its copied by the installer. This makes the file hidden Take a look at : http://wixtoolset.org/documentation/manual/v3/xsd/wix/file.html (Look at the attribute Hidden) However, i do not see an easy way to set this attribute on a file element when the file is being harvested. The only way i know of is to ...


0

Unfortunately, the answer is no. RemoveExistingProducts does not trigger during a maintenance operation. You will certain lines in the log file which indicate that: Skipping RemoveExistingProducts action: current configuration is maintenance mode or an uninstall What you are trying to do is usually achieved by making use of a bootstrapper application. ...


1

It's probably a bug in WiX v4. WiX v4.0 is still in active development and is pre-beta. Please file a bug at http://wixtoolset.org/issues/ so we don't lose it.


2

Try it this way: <xsl:stylesheet version="1.0" xmlns:xsl="http://www.w3.org/1999/XSL/Transform" xmlns:wix="http://schemas.microsoft.com/wix/2006/wi"> <xsl:output method="xml" version="1.0" encoding="UTF-8" indent="yes"/> <xsl:strip-space elements="*"/> <!-- identity transform --> <xsl:template match="@*|node()"> ...


0

Thanks to Chris for suggesting testing on a fresh image. That led me to the answer. My problem was that a custom action (which was running an executable) was failing. Once I put a condition of 'NOT installed' to prevent that custom action running on uninstall it started to work <InstallExecuteSequence> <Custom Action="CA_RunRegisterDLLScript" ...


0

I don't know that in the context of an installation bootstrapper. OTOH, either a VFP database and tables or VFP tables (free) are just plain files that are copied/moved from a folder. You don't need to have an exe for that to create them programmatically. Also having those files as part of the setup might not be a good idea as well. If some files are ...


0

Found a way to do it with vbscript, just out of curiosity: The "property #9" is the package code (revision number). Set wi = CreateObject("WindowsInstaller.Installer") Set summary = wi.SummaryInformation("your.msi", 2) summary.Property(9) = "{PUT-NEW-GUID-HERE}" summary.Persist


0

Since you mentioned Advanced Installer, here is how you can install a PHP website or install SQL Express. As Kiran mentioned, this is much easy to use than Wix, but it still gives you a lot of power to configure your installer. However, you need to purchase license after the trial expires (and you are satisfied with the results).


0

This issue is caused by Virus protection applications stopping the installer from writing keys. Temporarily disabling the virus checker (McAfee in my case) solved the problem.


1

I'm guessing that the requirement here is to install the same MSI multiple times, which means they need to change that set of guids. However the more normal way to solve that problem is with MSINEWINSTANCE. https://msdn.microsoft.com/en-us/library/aa370326(v=vs.85).aspx https://msdn.microsoft.com/en-us/library/aa369528(v=vs.85).aspx so that you are not ...


0

I suggest following up on the cause ofthe error message. The docs say this is consequence of something in the CCPSearch table. Assuming Windows Installer isn't behaving totally strangely: Open the MSI file with Orca to see if there is something in the CCPSearch table, and if so figure out where it came from and get rid of it. I assume there is a ...


0

Welcome to the world of windows installer. Firstly, you can spend your time on Wix and windows installer. Windows installer is like a framework which provides all the infrastructure to allow developers to install their applications by making use of .msi packages on the windows platform. Wix is kind of an editor which can be used to build .msi packages ...


1

It seems to be wrong to set the Languages via the *.wix file with the current WIX version. You need to: create the msi file add (embedded) the translations set the language IDs in the msi file A good description can you find here: https://www.hass.de/content/how-create-msi-packages-multilingual-user-interface-mui


0

I needed it because MSI created cache in respective package code which restricts us to make another instance of application using MSI so I did this by using (var database = new Database(@"D:\\Nirvana\\WorkingCopy\\trunk\\proj1\\installer.msi", DatabaseOpenMode.Direct)) { database.SummaryInfo.RevisionNumber = "{" + Guid.NewGuid() + "}"; }


0

Why do you even have the need to set the package code? Its auto generated during each build. Take a look at the documentation of the Package element: http://wixtoolset.org/documentation/manual/v3/xsd/wix/package.html "The package code GUID for a product or merge module. When compiling a product, this attribute should not be set in order to allow the ...


-1

Try change DllEntry from WixQuietExec to CAQuietExec and property use QtExecCmdLine please reference to https://www.firegiant.com/wix/tutorial/standard-libraries/silence-please/


0

There could be few other reasons such as some dependency missing or the user context under which the bootstrapper executes is different from the working scenario. The first thing i would do here is to inspect the windows installer logs. To generate , windows installer logs, you can follow the following link: ...


0

The error is self explanatory. In your source file for the merge module, what value do you have for the Module/Package@Languages attribute? The error also suggests that you can fix this by making the Languages attribute to 0. Hope this helps.


0

Not sure this is an answer but there's too much for a comment. First, do the upgrades with verbose logging, msiexec.exe command with a /L*vx to see what's going on because there are a number of things that don't make sense. Your custom action is after InstallFinalize, which means it is after the install has completed and committed so it cannot cause the ...


2

Thanks for your clue. By reading the log I found out that the exe writes to another drive than the single msi's do. I don't know weather this is a "clean" solution but for me hardcoding the TARGETDIR to "D:\" does the job. All files are copied to the destinationfolder. <Property Id="TARGETDIR">D:\</Property> Before that I had used a custom ...


0

Give directory for shortcuts.and assign it like you have done for other components. Also since you cant give shortcut as keypath, you could keep registry in shortcut component as keypath.


1

You can't. This exactly message is coming from windows installer service itself, it's the same for all installations, and you can't change it, it's always in the OS language.


0

You can use Project Reference Variables for that. No need to specify constants. Sample steps: Add a project reference (of the application) to your setup project Right Click 'References', 'Add References' Use project reference values in your wxs file $(var.ProjectName.Configuration) <?if $(var.ProjectName.Configuration) = Debug ?> ...


0

This ONLY works for LocalMachine. If you try to install to the CurrentUser the dialog will still appear.


0

Found the issue with my patching. For anyone who runs in similar issue, you need to have the ProductCode specified in the PatchCreation's PatchSequence element, it is the same GUID as the one used for ID of product for building MSI. I didn't have this reference, which apparently caused issues. Now it doesn't elevate for admin. Combine this with the steps ...


0

Weebly, to my knowledge, can't handle custom login screens. Not familiar with Wix, but I assume it is the same. Consider looking into Wordpress. It is much more friendly to non-programmers, and is very easy to customize. The default WordPress build comes with a login system. Customization looks easy enough. Hope that helps.


2

The overall problem with your launch conditions is that they are the wrong way around. A condition has to evaluate to true for the install to proceed. For example, your Server 2008 condition needs changing to be something like VersionNT=600 AND MsiNTProductType>1 so that it a) includes a server check and b) the entire expression evaluates to true if if it's ...


1

It is not possible to use a component in multiple places (directories). The alternative is to create multiple components moving the Directory attribute from the ComponentGroup to the Component tag. <ComponentGroup Id="ProductComponents"> <Component Id="CMP_FooSetup" Directory="INSTALLFOLDER"> <File Id="FILE_Foo.exe" ...


0

You can inspect the version of the files which get included in your .msi package by making use of a tool called Orca. Orca is part of the windows installer SDK. To install Orca, you will have to download the latest Windows SDK and choose a specific optional component to install(I dont recollect the exact optional component to choose to get Orca, I recall ...


0

Installer .exe's created with WiX can be run from the command line without requiring user input by using one of these command line parameters: /quiet - Displays no UI whatsoever /passive - Displays a UI but requires no user input. Essentially just displays an install progress bar This answer is based on WiX 3.9.


0

Well, no because of the following reasons: -Try compiling a project the way you are trying it and you will hit the following error: The Upgrade/@Id attribute's value, '[UPGRADEGUID]', is not a legal guid value. -Secondly, look up the description of the Upgrade table on MSDN https://msdn.microsoft.com/en-us/library/aa372379%28v=vs.85%29.aspx The ...


1

There is no need for a custom action. You will have to include one of the Wix provided dialog sets as part of your installer source code. http://wixtoolset.org/documentation/manual/v3/wixui/dialog_reference/wixui_minimal.html Your requirement can very well be met by making use of the WixUI_Minimal dialog set. For an example of how to include a built in ...


1

We integrated both into our build system. But we decided to promote innosetup exe files for non business customers and msi only on demand for one simple reason. You can't ship a multi-localized version of setup program with MSI. You would need one installer for every language and this sucks huge. There might be some heavy hacking allowing you to rewrite ...


0

Isnt your situation handled by a major ugprade? Thats what major upgrade is meant for. If your upgrade table is correctly configured, you can upgrade an older version of your application. If no older version is found, the application gets installed just like a fresh installation. Or is there something more to this question that i am not seeing?


1

Approach 3: Do what the batch file does in Burn instead. Use MsiPackage and ExePackage elements directly instead of trying to run a batch file. (An ExePackage can't run a batch file anyway.)


1

The most common reason for a reboot after repairs is a file was accessed by the installer that the application still had a lock on. This is usually identifiable in the repair logs (sometimes it takes a bit of looking to find the file the installer had trouble with). If you are unable to find the information you need in your logs, post them here and we will ...


2

Two techniques: 1) Identify the cause of the reboot and avoid it. ( Examples: stop service, kill process ) 2) Suppress reboot using the REBOOT property. Note repair may not be effective until after the reboot. 1 is usually the best way to go.


1

It's not good to pass an empty value as a parameter. Instead you can pass a value to make the checkbox unchecked. Lets say if you pass value 0 as the property value, then the checkbox goes to unchecked state. Here is an example : Your product.wxs file should have the following lines. <Property Id="MY_PROP" Value="1"/> <SetProperty Id="MY_PROP" ...


0

You can't preserve the shortcut - at least not in the default case of advertised shortcuts. These shortcuts contain a reference to the product, component and feature, and sometimes an icon that may be in the binary table of the cached MSI. At least two of these will change over an upgrade. That leaves you with non-advertised shortcuts or ones you create ...


0

Looks I solved my own question; at least for Wix RadioButtonGroup elements. In my product.wxs equivalent file, I just add these two lines <Property Id="RT_DB_LOGON_TYPE" Value="SqlAuth" /> <Condition Message="!(loc.RT_DB_LOGON_TYPE_Messg)">RT_DB_LOGON_TYPE ~= "SqlAuth" OR RT_DB_LOGON_TYPE ~= "WinAuth"</Condition> In the log file, ...