1,169 reputation
1417
bio website
location Fürth, Germany
age 55
visits member for 2 years, 1 month
seen 9 hours ago

Nov
30
revised How to send response APDU containing return data AND status word other than 0x9000?
added numeric range for completeness
Nov
30
suggested suggested edit on How to send response APDU containing return data AND status word other than 0x9000?
Nov
15
answered How to get pin intents from smart card or token?
Nov
8
comment How to check if smartcard has applet on it
As always: support of partial DF name selection is optional (concerning 7816-4), but at least may be indicated in card capabilities in the ATR.
Oct
30
answered compiling py to pyc error
Oct
3
comment Standards for smartcard communication
You were lucky this time, which is why I wrote "possibly different". (Manufacturers may be smart enough to converge.) But from the technical point of view they could be totally different, because they do not depend on the card.
Oct
3
answered Standards for smartcard communication
Sep
30
comment How to create EF in SCOSTA smartcard
Writing data is definitely a separate command, UPDATE BINARY or APPEND RECORD depending on the chosen file type. The interface sees only bytes, so some instance has to do the conversion. of your text.
Sep
30
comment How to create EF in SCOSTA smartcard
I don't understand your two trailing zeroes, in the question it was only one, which I assumed to be LE. Take a look at Scosta specification. File type byte is not defined there, but as I said 0 seems an uninformative choice. File size (now known to be in tag 80) is a must for EFs, however. A short EF identifier can't be simply glued on but must be wrapped in a DO with tag 88 (which also needs adjustment of tag 62's length. Zero is no valid value, however, if you don't need a short EF identifier, specify a DO 88 with length zero.
Sep
29
answered How to create EF in SCOSTA smartcard
Sep
18
comment Java Card ECKey with NIST P256 Curve. How to encode a negative coefficient?
a seems to be missing in front of x**3
Sep
18
answered Java Card ECKey with NIST P256 Curve. How to encode a negative coefficient?
Sep
16
revised PPSE and CRS relation when using INTERNAL mode
One acronym resolved, one to go
Sep
16
comment PPSE and CRS relation when using INTERNAL mode
While I edited the hopefully correct PPSE meaning, I would suggest to resolve CRS also; at least I was not able to find a matching definition in acronym finder; there is nearly no meaning left in the question without knowledge of these acronyms.
Sep
16
suggested suggested edit on PPSE and CRS relation when using INTERNAL mode
Sep
13
comment Assign additional info to a class field in Python
I'm not sure, whether you may change the class definition. If you do, you should take a look at the property function and define get functions for the attributes in question. These get functions could store the desired information e.g. in their docstrings.
Sep
8
answered How come I do not recieve a response from the SIM (ISO-7816)?
Aug
20
comment efficient way to count the element in a dictionary in Python using a loop
In addition to correcting the sequence of plus and assignment, just this modification would be necessary: mydict = defaultdict(int) to avoid exception on first access of each element.
Aug
15
answered Formal interpretation of `in` in Python's `for` loops
Aug
13
awarded  Scholar